Effects of mobile phone radiation on certain hematological parameters

2019 · Harm · Low evidence

← Research stream
HarmLow evidencePaper 1702

In an in vitro matched case-control laboratory experiment using a 4G mobile phone (2.3–2.4 GHz) for 60 minutes, exposed blood samples showed a significant change in hematological components compared with unexposed controls. Platelet count decreased, while hem…

Study snapshot

Publicationmanual · 2019
Study typecase_control
Reported directionHarm
Evidence ratingLow

Abstract

Effects of mobile phone radiation on certain hematological parameters Christopher B, Sheena MY, Uddin Khandaker M, Bradley DA, Chew MT, Jojo PJ. Effects of mobile phone radiation on certain hematological parameters. Radiation Physics and Chemistry. Published online September 14, 2019. 108443. doi.org. Highlights • Mobile phone radiation affects blood hemoglobin level, white blood cell and platelets count and erythrocytes sedimentation rate. • Effects of mobile phone radiation on hematological factors studied in a controlled condition in the laboratory. • A matched case control approach was adopted for the investigation. • Long time and over exposure to mobile phone radiation may affect the individual health. Abstract Exorbitant chronic exposure to any sort of radiation is hazardous to human health. Besides ionizing radiation, exposures to electromagnetic radiation mainly from the use of mobile phones have become a matter of great health concern, especially its extortionate use even by children. At the same time there are several myths related to the ill effects including carcinogenicity of the prolonged exposure continuously. The objective of this investigation was to find the effect on certain vital hematological parameters namely hemoglobin level, white blood cell (WBC) count, platelet count and erythrocytes sedimentation rate (ESR) level due to the prolonged exposure to mobile radiations through in vitro examination of human blood samples. Matched case control methodology was adopted for the study. Blood samples were collected by clinicians from 27 voluntary subjects for investigation. From each, one sample was kept un-exposed while the other three samples were exposed to mobile microwave radiations for 60 min continuously in identical and controlled conditions. A 4G hand phone of a very popular brand having transmission frequency range from 2.3 to 2.4 GHz including uplink and downlink was used. Hematological analyses were carried out on fresh samples immediately after collection. For comparison of the levels of hematological parameters, blood exposed to 1 h of phone radiation and control were analysed. Experimental results show that there is a significant change on the hematological components. The exposed blood samples were found to have decrease in platelet count only. Hemoglobin level, ESR rate and the WBC counts were found to be increased. While these observations are performed in a controlled laboratory conditions, the tremendous growth in number of mobile phone users, the effects could be many more folds especially in work places and cities even through passive exposure. sciencedirect.com

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typecase_control
Effect directionharm
PopulationHuman blood samples from voluntary subjects (in vitro)
Sample size27
ExposureRF · 2350 MHz · 60 min continuous exposure
Evidence strengthLowConfidence: 78% · Peer reviewed: yes

Main findings

In an in vitro matched case-control laboratory experiment using a 4G mobile phone (2.3–2.4 GHz) for 60 minutes, exposed blood samples showed a significant change in hematological components compared with unexposed controls. Platelet count decreased, while hemoglobin level, ESR, and WBC count increased.

Outcomes measured

  • hemoglobin level
  • white blood cell (WBC) count
  • platelet count
  • erythrocytes sedimentation rate (ESR)

Limitations

  • In vitro examination of human blood samples (not an in vivo health outcome study)
  • Small sample size (27 subjects)
  • Exposure metrics such as SAR or power density not reported
  • Only one exposure duration reported (60 minutes)
View raw extracted JSON
{
  "study_type": "case_control",
  "exposure": {
    "band": "RF",
    "source": "mobile phone",
    "frequency_mhz": 2350,
    "sar_wkg": null,
    "duration": "60 min continuous exposure"
  },
  "population": "Human blood samples from voluntary subjects (in vitro)",
  "sample_size": 27,
  "outcomes": [
    "hemoglobin level",
    "white blood cell (WBC) count",
    "platelet count",
    "erythrocytes sedimentation rate (ESR)"
  ],
  "main_findings": "In an in vitro matched case-control laboratory experiment using a 4G mobile phone (2.3–2.4 GHz) for 60 minutes, exposed blood samples showed a significant change in hematological components compared with unexposed controls. Platelet count decreased, while hemoglobin level, ESR, and WBC count increased.",
  "effect_direction": "harm",
  "limitations": [
    "In vitro examination of human blood samples (not an in vivo health outcome study)",
    "Small sample size (27 subjects)",
    "Exposure metrics such as SAR or power density not reported",
    "Only one exposure duration reported (60 minutes)"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mobile phone radiation",
    "4G",
    "microwave radiation",
    "2.3 GHz",
    "2.4 GHz",
    "hematological parameters",
    "hemoglobin",
    "WBC",
    "platelets",
    "ESR",
    "in vitro",
    "matched case control"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1016/j.radphyschem.2019.108443
PubMed: Not supplied

Read the original paper →

Related papers

← Back to the Research Library