Preliminary Study of Coagulation Monitoring by Antenna for Treatment during Microwave Coagulation Therapy.
← Research streamDuring microwave radiation in microwave coagulation therapy, the reflection coefficient of the treatment antenna changes significantly. Numerical calculations and measurements suggested the possibility of monitoring coagulation by observing these reflection c…
Study snapshot
Abstract
Microwave coagulation therapy (MCT) has been employed mainly for treatment of small size tumors. In the treatment, thin microwave antenna is inserted into the tumor and microwave energy heats up the tumor up to at least 60 degrees C for generation of enough coagulated volume including the target tumor. During the microwave radiation, reflection coefficient of treatment antenna changes significantly. In this paper, possibility of coagulation monitoring was found observing the reflection coefficient change of the antenna by numerical calculations and measurements.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
During microwave radiation in microwave coagulation therapy, the reflection coefficient of the treatment antenna changes significantly. Numerical calculations and measurements suggested the possibility of monitoring coagulation by observing these reflection coefficient changes.
Outcomes measured
- Change in antenna reflection coefficient during microwave coagulation therapy
- Feasibility of coagulation monitoring via antenna reflection coefficient
Limitations
- Frequency and exposure parameters (e.g., power, SAR, duration) not reported in the abstract
- No sample size or subject/phantom details provided in the abstract
- Outcome focused on monitoring/measurement feasibility rather than health effects
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "microwave",
"source": "microwave coagulation therapy antenna",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Change in antenna reflection coefficient during microwave coagulation therapy",
"Feasibility of coagulation monitoring via antenna reflection coefficient"
],
"main_findings": "During microwave radiation in microwave coagulation therapy, the reflection coefficient of the treatment antenna changes significantly. Numerical calculations and measurements suggested the possibility of monitoring coagulation by observing these reflection coefficient changes.",
"effect_direction": "unclear",
"limitations": [
"Frequency and exposure parameters (e.g., power, SAR, duration) not reported in the abstract",
"No sample size or subject/phantom details provided in the abstract",
"Outcome focused on monitoring/measurement feasibility rather than health effects"
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"microwave coagulation therapy",
"antenna",
"reflection coefficient",
"coagulation monitoring",
"tumor ablation",
"numerical calculations",
"measurements"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.2174/1874120701004020013
PubMed: 20300228
Related papers
- The imprint of radiofrequency in the management of hepatocellular carcinoma. 2006
- Radiation Effect Analysis on Human Head Caused by Different Frequencies of Mobile Phone Antenna 2022
- Radiofrequency Interference in the Clinical Laboratory 2019
- A novel mobile phone antenna for effectively reducing specific absorption rate 2018
- Mortality by neoplasia and cellular telephone base stations in the Belo Horizonte municipality, Minas Gerais state, Brazil. 2011
- Investigation of the spinal cord as a natural receptor antenna for incident electromagnetic waves and possible impact on the central nervous system. 2012