Microwave radiation and heart-beat rate of rabbits.

The Journal of microwave power · 1980 · Mixed · Very low evidence

← Research stream
MixedVery low evidencePaper 6046

Field-induced changes in heart-beat rate were observed at 80 mW/cm2 continuous-wave exposure but not at lower average power densities (5 mW/cm2). The authors note a possible peak positive chronotropic effect with pulsed microwaves triggered 100 and 200 ms aft…

Study snapshot

PublicationThe Journal of microwave power · 1980
Study typeanimal
Reported directionMixed
Evidence ratingVery low

Abstract

Each of three adult New Zealand rabbits, 2 male and 1 female albinos, was exposed dorsally or ventrally, to 2450-MHz plane waves for 20 min under each of several field conditions: 1) to continuous waves (CW) at 5 mW/cm2; 2) to pulsed waves (PW) of 1-microsecond width that recurred 700 pps at an average of 5 mW/cm2 and at a peak of 7.1 W/cm2; 3) to PW of 10-microseconds width at a peak of 13.7 W/cm2 that were synchronized with and triggered by the R wave of the electrocardiogram (EKG) at various delay times (0, 100, and 200 ms; and 4) to CW at 80 mW/cm2. Carbon-loaded Teflon electrodes were used to record the EKG from forelimbs of an animal before, during, and after irradiation whilst it was maintained in a constant exposure geometry in a wooden squeeze box. Field induced changes in the heart-beat rate were observed at 80 mW/cm2 but not a lower average power densities, although a peak positive chronotropic effect might have been occasioned by PM introduced at 100 and 200 ms after the R wave peak. No cumulative effect was observed over a period of four months. Thermographic analysis revealed relatively little absorption of microwave energy by the myocardium irrespective of anatomical aspect of exposure.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionmixed
PopulationAdult New Zealand rabbits (2 male, 1 female albinos)
Sample size3
Exposuremicrowave · 2450 MHz · 20 min
Evidence strengthVery lowConfidence: 74% · Peer reviewed: yes

Main findings

Field-induced changes in heart-beat rate were observed at 80 mW/cm2 continuous-wave exposure but not at lower average power densities (5 mW/cm2). The authors note a possible peak positive chronotropic effect with pulsed microwaves triggered 100 and 200 ms after the R wave. No cumulative effect was observed over four months, and thermography suggested relatively little myocardial absorption regardless of exposure aspect.

Outcomes measured

  • heart-beat rate
  • electrocardiogram (EKG)
  • myocardial microwave energy absorption (thermographic analysis)

Limitations

  • Very small sample size (n=3)
  • Animal study; generalizability to humans unclear
  • Some findings described as possible (uncertain) rather than definitive
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "microwave",
    "source": null,
    "frequency_mhz": 2450,
    "sar_wkg": null,
    "duration": "20 min"
  },
  "population": "Adult New Zealand rabbits (2 male, 1 female albinos)",
  "sample_size": 3,
  "outcomes": [
    "heart-beat rate",
    "electrocardiogram (EKG)",
    "myocardial microwave energy absorption (thermographic analysis)"
  ],
  "main_findings": "Field-induced changes in heart-beat rate were observed at 80 mW/cm2 continuous-wave exposure but not at lower average power densities (5 mW/cm2). The authors note a possible peak positive chronotropic effect with pulsed microwaves triggered 100 and 200 ms after the R wave. No cumulative effect was observed over four months, and thermography suggested relatively little myocardial absorption regardless of exposure aspect.",
  "effect_direction": "mixed",
  "limitations": [
    "Very small sample size (n=3)",
    "Animal study; generalizability to humans unclear",
    "Some findings described as possible (uncertain) rather than definitive"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "rabbit",
    "microwave radiation",
    "2450 MHz",
    "continuous wave",
    "pulsed wave",
    "power density",
    "heart rate",
    "chronotropic effect",
    "electrocardiogram",
    "thermography"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: Not supplied
PubMed: 6904510

Read the original paper →

Related papers

← Back to the Research Library