Modification of the repeated acquisition of response sequences in rats by low-level microwave exposure.
← Research streamRats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completi…
Study snapshot
Abstract
The acute effects of microwave exposure on a repeated acquisition baseline were investigated in three rats. Each session the animals acquired a different four-member response sequence. Each of the first three correct responses advanced the sequence to the next member, and the fourth correct response produced food reinforcement. Incorrect responses produced a three-second timeout. Baseline and control sessions were characterized by a decrease in errors within each session. The animals were acutely exposed to a 2.8 GHz pulsed-microwave field prior to test sessions, with average power densities ranging from 0.25 to to 10 mW/cm2. In comparison to control sessions, 1/2 hour of exposure to microwave radiation at power densities of 5 and 10 mW/cm2 increased errors and altered the pattern of within-session acquisition. Exposure to the 10 mW/cm2 power density decreased the rate of sequence completion in all animals. The results of exposures at 0.25, 0.5, and 1 mW/cm2 power densities were generally within the control range. The results are interpreted as indicating a disruption in the discriminative stimulus control of the repeated acquisition behavior.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.
Outcomes measured
- Repeated acquisition of response sequences (errors)
- Pattern of within-session acquisition
- Rate of sequence completion
Limitations
- Very small sample size (three rats)
- Acute exposure only; no long-term effects assessed
- Exposure metric reported as power density; SAR not reported
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "microwave",
"source": null,
"frequency_mhz": 2800,
"sar_wkg": null,
"duration": "1/2 hour (acute exposure prior to test sessions)"
},
"population": "Three rats",
"sample_size": 3,
"outcomes": [
"Repeated acquisition of response sequences (errors)",
"Pattern of within-session acquisition",
"Rate of sequence completion"
],
"main_findings": "Rats acutely exposed to a 2.8 GHz pulsed-microwave field at average power densities of 5 and 10 mW/cm2 showed increased errors and altered within-session acquisition compared with control sessions. Exposure at 10 mW/cm2 decreased the rate of sequence completion in all animals, while results at 0.25, 0.5, and 1 mW/cm2 were generally within the control range.",
"effect_direction": "harm",
"limitations": [
"Very small sample size (three rats)",
"Acute exposure only; no long-term effects assessed",
"Exposure metric reported as power density; SAR not reported"
],
"evidence_strength": "very_low",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"microwave",
"pulsed microwave",
"2.8 GHz",
"2800 MHz",
"power density",
"mW/cm2",
"rats",
"behavior",
"learning",
"repeated acquisition",
"response sequences"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1002/bem.2250010109
PubMed: 7284018
Related papers
- Compound exposure of 2.8 GHz and 9.3 GHz microwave causes learning and memory impairment in 2025
- In vitro study of microwave effects on calcium efflux in rat brain tissue. 1981
- Behavioral effects of chronic exposure to 0.5 mW/cm2 of 2,450-MHz microwaves. 1987
- Changes in rat spatial learning and memory as well as serum exosome proteins after simultaneous exposure to 1.5 GHz and 4.3 GHz microwaves 2022
- Evaluation of cognitive functions and EEG records in rats exposed to 2.45 GHz electromagnetic field 2022
- The dose-dependent effect of 1.5-GHz microwave exposure on spatial memory and the NMDAR pathway in Wistar rats 2022