Exposure of baboons to combined 60 Hz electric and magnetic fields does not produce work stoppage or affect operant performance on a match-to-sample task.

Bioelectromagnetics · 1995 · No effect · Low evidence

← Research stream
No effectLow evidencePaper 5444

Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.

Study snapshot

PublicationBioelectromagnetics · 1995
Study typeanimal
Reported directionNo effect
Evidence ratingLow

Abstract

We examined the effects of combined 60 Hz electric and magnetic field (EMF) exposure on performance of delayed match-to-sample (MTS) procedure involving the flash rate of a light as the stimulus. Six baboons (Papio cynocephalus) fully acquired the task; four others functioned accurately only when cued. All ten subjects were assigned to EMF-exposed or sham-exposed groups of five and were used to test for a work-stoppage effect that was previously observed with initial exposure to electric fields (EF) of 30 or 60 kV/m. Here, we report the results of two experiments, each consisting of 6 week preexposure, exposure, and postexposure periods. We found no evidence of work stoppage with fields of 6 kV/m and 50 microT (0.5 G) or with 30 kV/m and 100 microT (1.0 G). In neither experiment was there evidence of an adverse effect of 60 Hz EMF exposure on MTS performance.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionno_effect
PopulationBaboons (Papio cynocephalus)
Sample size10
ExposureELF · 0.06 MHz · Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified).
Evidence strengthLowConfidence: 78% · Peer reviewed: yes

Main findings

Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.

Outcomes measured

  • Work stoppage
  • Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)

Limitations

  • Small sample size (10 baboons; 5 exposed and 5 sham per experiment/grouping as described)
  • Exposure duration within the exposure period not specified in the abstract
  • Some animals required cueing to perform accurately, which may affect generalizability of performance outcomes
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.06,
    "sar_wkg": null,
    "duration": "Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified)."
  },
  "population": "Baboons (Papio cynocephalus)",
  "sample_size": 10,
  "outcomes": [
    "Work stoppage",
    "Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)"
  ],
  "main_findings": "Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.",
  "effect_direction": "no_effect",
  "limitations": [
    "Small sample size (10 baboons; 5 exposed and 5 sham per experiment/grouping as described)",
    "Exposure duration within the exposure period not specified in the abstract",
    "Some animals required cueing to perform accurately, which may affect generalizability of performance outcomes"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "60 Hz",
    "ELF",
    "electric field",
    "magnetic field",
    "baboons",
    "Papio cynocephalus",
    "work stoppage",
    "operant performance",
    "delayed match-to-sample"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.25,
      "reason": "Study examines combined 60 Hz electric and magnetic fields at kV/m and microtesla levels relevant to power-frequency environments, though no specific workplace setting is stated."
    }
  ]
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1002/bem.2250160707
PubMed: 8787567

Read the original paper →

Related papers

← Back to the Research Library