← Research streamElectric field strength near DECT handsets ranged from 0.26–2.30 V/m at 0.05 m and 0.18–0.26 V/m at 1 m; near DECT base units from 1.78–5.44 V/m at 0.05 m and 0.19–0.41 V/m at 1 m. Near mobile phones in GSM voice mode, electric field strength ranged from 2.34…
Study snapshot
Abstract
BACKGROUND: Mobile telephones belong to the most frequently used personal devices. In their surroundings they produce the electromagnetic field (EMF), in which exposure range there are not only users but also nearby bystanders. The aim of the investigations and EMF measurements in the vicinity of phones was to identify the electric field levels with regard to various working modes. MATERIAL AND METHODS: Twelve sets of DECT (digital enhanced cordless telecommunications) cordless phones (12 base units and 15 handsets), 21 mobile telephones produced by different manufactures, and 16 smartphones in various applications, (including multimedia) in the conditions of daily use in living rooms were measured. Measurements were taken using the point method in predetermined distances of 0.05-1 m from the devices without the presence of users. RESULTS: In the vicinity of DECT cordless phone handsets, electric field strength ranged from 0.26 to 2.30 V/m in the distance of 0.05 m - 0.18-0.26 V/m (1 m). In surroundings of DECT cordless telephones base units the values of EMF were from 1.78-5.44 V/m (0.05 m) to 0.19- 0.41 V/m (1 m). In the vicinity of mobile phones working in GSM mode with voice transmission, the electric field strength ranged from 2.34-9.14 V/m (0.05 m) to 0.18-0.47 V/m (1 m) while in the vicinity of mobile phones working in WCDMA (Wideband Code Division Multiple Access) mode the electric field strength ranged from 0.22-1.83 V/m (0.05 m) to 0.18-0.20 V/m (1 m). CONCLUSIONS: The mean values of the electric field strength for each group of devices, mobile phones and DECT wireless phones sets do not exceed the reference value of 7 V/m, adopted as the limit for general public exposure.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Electric field strength near DECT handsets ranged from 0.26–2.30 V/m at 0.05 m and 0.18–0.26 V/m at 1 m; near DECT base units from 1.78–5.44 V/m at 0.05 m and 0.19–0.41 V/m at 1 m. Near mobile phones in GSM voice mode, electric field strength ranged from 2.34–9.14 V/m at 0.05 m and 0.18–0.47 V/m at 1 m; in WCDMA mode from 0.22–1.83 V/m at 0.05 m and 0.18–0.20 V/m at 1 m. The authors report that mean electric field strengths for each device group did not exceed the 7 V/m reference value for general public exposure.
Outcomes measured
- Electric field strength (V/m) at 0.05–1 m from devices
- Comparison to general public reference level (7 V/m)
Limitations
- Measurements were performed without the presence of users (may not reflect typical use conditions).
- Measurements were conducted in living rooms under daily-use conditions; generalizability to other environments is not described.
- Only electric field strength was reported; no SAR or health outcomes were assessed.
- Frequencies and detailed measurement instrumentation/uncertainty are not provided in the abstract.
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": null,
"source": "DECT cordless telephones and mobile phones (GSM, WCDMA)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": 64,
"outcomes": [
"Electric field strength (V/m) at 0.05–1 m from devices",
"Comparison to general public reference level (7 V/m)"
],
"main_findings": "Electric field strength near DECT handsets ranged from 0.26–2.30 V/m at 0.05 m and 0.18–0.26 V/m at 1 m; near DECT base units from 1.78–5.44 V/m at 0.05 m and 0.19–0.41 V/m at 1 m. Near mobile phones in GSM voice mode, electric field strength ranged from 2.34–9.14 V/m at 0.05 m and 0.18–0.47 V/m at 1 m; in WCDMA mode from 0.22–1.83 V/m at 0.05 m and 0.18–0.20 V/m at 1 m. The authors report that mean electric field strengths for each device group did not exceed the 7 V/m reference value for general public exposure.",
"effect_direction": "unclear",
"limitations": [
"Measurements were performed without the presence of users (may not reflect typical use conditions).",
"Measurements were conducted in living rooms under daily-use conditions; generalizability to other environments is not described.",
"Only electric field strength was reported; no SAR or health outcomes were assessed.",
"Frequencies and detailed measurement instrumentation/uncertainty are not provided in the abstract."
],
"evidence_strength": "insufficient",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"DECT",
"cordless phone",
"mobile phone",
"smartphone",
"GSM",
"WCDMA",
"electric field strength",
"V/m",
"bystander exposure",
"distance measurements",
"general public limit 7 V/m"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.25,
"reason": "Published in an occupational medicine journal and discusses exposure levels relevant to bystanders/users, though measurements were in living rooms."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.13075/mp.5893.00364
PubMed: 26674167
Related papers
- Mobile phones: A trade-off between speech intelligibility and exposure to noise levels and to radio-frequency electromagnetic fields 2019
- Lost opportunities for cancer prevention: historical evidence on early warnings with emphasis on radiofrequency radiation 2021
- Study of potential health effects of electromagnetic fields of telephony and Wi-Fi, using chicken embryo development as animal model 2017
- Radiofrequency exposure levels in Amsterdam schools 2017
- Effect of DECT cordless phone radiation on exposed, laboratory cultivated maize plants 2017
- Effect of DECT cordless phone radiation on exposed, laboratory cultivated upland cotton plants 2017