Microneedle array for measuring wound generated electric fields.
← Research streamA fabricated microneedle array was used to measure transdermal skin potentials near superficial wounds in human subjects. Recordings confirmed a lateral electric field in human skin that decays with distance from the wound edge and is directed toward the woun…
Study snapshot
Abstract
A microneedle array has been fabricated and applied to the measurement of transdermal skin potentials in human subjects. Potential changes were recorded in the vicinity of superficial wounds, confirming the generation of a lateral electric field in human skin. The measured electric field decays with distance from the wound edge, and is directed towards the wound. The measurement of endogenous fields in skin is a prelude to the study of the therapeutic efficacy of applied electric fields to chronic non-healing wounds.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
A fabricated microneedle array was used to measure transdermal skin potentials near superficial wounds in human subjects. Recordings confirmed a lateral electric field in human skin that decays with distance from the wound edge and is directed toward the wound.
Outcomes measured
- Transdermal skin potentials
- Electric field magnitude/direction near superficial wounds
- Spatial decay of electric field with distance from wound edge
Limitations
- Sample size not reported in abstract
- No health outcomes or therapeutic effects assessed; measurements only
- Wounds described as superficial; generalizability to chronic wounds not addressed
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "endogenous (wound-generated electric fields in human skin)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Human subjects",
"sample_size": null,
"outcomes": [
"Transdermal skin potentials",
"Electric field magnitude/direction near superficial wounds",
"Spatial decay of electric field with distance from wound edge"
],
"main_findings": "A fabricated microneedle array was used to measure transdermal skin potentials near superficial wounds in human subjects. Recordings confirmed a lateral electric field in human skin that decays with distance from the wound edge and is directed toward the wound.",
"effect_direction": "unclear",
"limitations": [
"Sample size not reported in abstract",
"No health outcomes or therapeutic effects assessed; measurements only",
"Wounds described as superficial; generalizability to chronic wounds not addressed"
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"microneedle array",
"transdermal skin potential",
"endogenous electric field",
"wound electric field",
"human skin",
"bioelectricity",
"measurement device"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1109/iembs.2006.260205
PubMed: 17947077
Related papers
- Reflection Properties of the Human Skin From 40 to 110 GHz: A Confirmation Study 2021
- The human skin as a sub-THz receiver - Does 5G pose a danger to it or not? 2018
- Thermal and SAR-Based Limits for Human Skin Exposed to Terahertz Radiation 2025
- Setup and dosimetry for exposure of human skin in vivo to RF-EMF at 900 MHz. 2008
- Emerging cancer therapies: targeting physiological networks and cellular bioelectrical differences with non-thermal systemic electromagnetic fields in the human body - a comprehensive review 2024
- Electrical Control of Escherichia coli Growth Measured with Simultaneous Modulation and Imaging 2020