In Vivo Wireless Monitoring System of Cardiovascular Force Data.

Cardiovascular engineering and technology · 2015 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 3000

A fully implantable telemetric system with a bidirectional RF transceiver was developed and tested in a porcine model. The implant transmitted ECG and force data wirelessly over a 5 m range to a receiver, and simultaneous measurement of forces and physiologic…

Study snapshot

PublicationCardiovascular engineering and technology · 2015
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

Biotelemetry provides the possibility to measure physiological data in awake, free-ranging animals without the effects of anesthesia and repeated surgery. In this project a fully implantable, telemetric system to measure biomechanical force data of the moving structures of the heart along with the ECG of experimental animals was developed. The system is based on a microcontroller with a built in bidirectional radio frequency transceiver, which allows for the implant to both receive and send data wirelessly. ECG was acquired using electrodes placed directly onto the heart, and the forces were collected using a miniature force transducer. The system was tested in a porcine model (60 kg body weight), where the system transmitted ECG and force data at a range of 5 m between the implant and the receiver. The data was displayed and saved to the hard drive of a laptop computer using a custom built software user interface. It was shown feasible to wirelessly measure forces simultaneously with physiological data from the cardiovascular system of living animals. The current system was optimized to measure forces and ECG, and more channels can be added to increase the number of parameters recorded.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationPorcine model (pig; ~60 kg body weight)
Sample sizeNot supplied
ExposureRF
Evidence strengthInsufficientConfidence: 74% · Peer reviewed: yes

Main findings

A fully implantable telemetric system with a bidirectional RF transceiver was developed and tested in a porcine model. The implant transmitted ECG and force data wirelessly over a 5 m range to a receiver, and simultaneous measurement of forces and physiological cardiovascular data in vivo was reported as feasible.

Outcomes measured

  • Feasibility of wireless transmission of ECG data
  • Feasibility of wireless transmission of cardiovascular force (biomechanical) data
  • Transmission range (5 m) between implant and receiver

Limitations

  • Sample size not reported in abstract
  • RF frequency and exposure metrics (e.g., SAR) not reported
  • Focus is on device feasibility/engineering rather than health effects of RF exposure
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "RF",
    "source": "implantable biotelemetry system (bidirectional RF transceiver)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Porcine model (pig; ~60 kg body weight)",
  "sample_size": null,
  "outcomes": [
    "Feasibility of wireless transmission of ECG data",
    "Feasibility of wireless transmission of cardiovascular force (biomechanical) data",
    "Transmission range (5 m) between implant and receiver"
  ],
  "main_findings": "A fully implantable telemetric system with a bidirectional RF transceiver was developed and tested in a porcine model. The implant transmitted ECG and force data wirelessly over a 5 m range to a receiver, and simultaneous measurement of forces and physiological cardiovascular data in vivo was reported as feasible.",
  "effect_direction": "unclear",
  "limitations": [
    "Sample size not reported in abstract",
    "RF frequency and exposure metrics (e.g., SAR) not reported",
    "Focus is on device feasibility/engineering rather than health effects of RF exposure"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "biotelemetry",
    "implantable device",
    "wireless monitoring",
    "radio frequency transceiver",
    "ECG",
    "cardiovascular force",
    "porcine model"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1007/s13239-014-0207-5
PubMed: 26577097

Read the original paper →