The evaluation of biological efficiency of electromagnetic fields generated by implanted radiotelemetric transmitters used in space research on animals.

The Physiologist · 1992 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 5474

The study was carried out in 50 male rats abdominally implanted with biotelemetric systems (BTS) or mock-up. The animals were provided with 12/12 light/dark schedule during 6-week experiment. The electromagnetic field (EMF) frequency was 455 kHz, magnetic ind…

Study snapshot

PublicationThe Physiologist · 1992
Study typeanimal
Reported directionUnclear
Evidence ratingInsufficient

Abstract

The study was carried out in 50 male rats abdominally implanted with biotelemetric systems (BTS) or mock-up. The animals were provided with 12/12 light/dark schedule during 6-week experiment. The electromagnetic field (EMF) frequency was 455 kHz, magnetic induction near transducer was about 10(-2) mT. Circadian rhythm of the body temperature and locomotor activity was controlled in course of the experiment. The latter been finished, some tissues and the blood of the animals have been sampled to test corticosterone, testosterone, T3, T4 level in serum with radioimmunoassay and membrane permeability for Ca2+, Na+, K(+)-ATPase activity and charge changes in liver microsomes was detected. The probable ways of the EMF influence on whole body are discussed.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionunclear
Population50 male rats
Sample size50
Exposure0.455 MHz · 6-week experiment
Evidence strengthInsufficientConfidence: 62% · Peer reviewed: yes

Main findings

The study was carried out in 50 male rats abdominally implanted with biotelemetric systems (BTS) or mock-up. The animals were provided with 12/12 light/dark schedule during 6-week experiment. The electromagnetic field (EMF) frequency was 455 kHz, magnetic ind…

Outcomes measured

  • Circadian rhythm of body temperature
  • Locomotor activity
  • Serum corticosterone
  • Serum testosterone
  • Serum T3
  • Serum T4
  • Membrane permeability for Ca2+
  • Na+, K(+)-ATPase activity
  • Charge changes in liver microsomes

Limitations

  • No results are reported in the abstract (direction/magnitude of effects not stated).
  • Exposure metrics are limited to frequency and magnetic induction near the transducer; other dosimetry (e.g., SAR) not provided in the abstract.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": null,
    "source": "implanted radiotelemetric transmitters (biotelemetric systems)",
    "frequency_mhz": 0.455,
    "sar_wkg": null,
    "duration": "6-week experiment"
  },
  "population": "50 male rats",
  "sample_size": 50,
  "outcomes": [
    "Circadian rhythm of body temperature",
    "Locomotor activity",
    "Serum corticosterone",
    "Serum testosterone",
    "Serum T3",
    "Serum T4",
    "Membrane permeability for Ca2+",
    "Na+, K(+)-ATPase activity",
    "Charge changes in liver microsomes"
  ],
  "main_findings": null,
  "effect_direction": "unclear",
  "limitations": [
    "No results are reported in the abstract (direction/magnitude of effects not stated).",
    "Exposure metrics are limited to frequency and magnetic induction near the transducer; other dosimetry (e.g., SAR) not provided in the abstract."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.62,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "rats",
    "implanted transmitter",
    "biotelemetry",
    "radiotelemetric",
    "455 kHz",
    "magnetic induction",
    "circadian rhythm",
    "body temperature",
    "locomotor activity",
    "corticosterone",
    "testosterone",
    "thyroid hormones",
    "T3",
    "T4",
    "membrane permeability",
    "Na,K-ATPase",
    "liver microsomes"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: Not supplied
PubMed: 1589524

Read the original paper →