[Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].
← Research streamStable glow discharges in air at low pressure were obtained; the light signal showed one discharge pulse per half cycle of the applied voltage with asymmetry between positive and negative half cycles. Emission intensity was almost constant at locations with t…
Study snapshot
Abstract
In the present paper, stable glow discharges were obtained in air at low pressure with a dielectric barrier surface discharge device. Light emission from the discharge was detected by photomultiplier tubes and the research results show that the light signal exhibited one discharge pulse per half cycle of the applied voltage. The light pulses were asymmetric between the positive half cycle and the negative one of the applied voltage. The images of the glow surface discharge were processed by Photoshop software and the results indicate that the emission intensity remained almost constant for different places with the same distance from the powered electrode, while the emission intensity decreased with the distance from the powered electrode increasing. In dielectric barrier discharge, net electric field is determined by the applied voltage and the wall charges accumulated on the dielectric layer during the discharge, and consequently, it is important to obtain information about the net electric field distribution. For this purpose, optical emission spectroscopy method was used. The distribution of the net electric field can be deduced from the intensity ratio of spectral line 391.4 nm emitted from the first negative system of N2+ (B 2sigma u+ -->X 2sigma g+) to 337.1 nm emitted from the second positive system of N2 (C 3IIu-B 3IIg). The research results show that the electric field near the powered electric field is higher than at the edge of the discharge. These experimental results are very important for numerical study and industrial application of the surface discharge.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Stable glow discharges in air at low pressure were obtained; the light signal showed one discharge pulse per half cycle of the applied voltage with asymmetry between positive and negative half cycles. Emission intensity was almost constant at locations with the same distance from the powered electrode and decreased with increasing distance. Using optical emission spectroscopy (391.4 nm/337.1 nm intensity ratio), the net electric field was inferred to be higher near the powered electrode than at the edge of the discharge.
Outcomes measured
- Electric field distribution in dielectric barrier surface glow discharge
- Optical emission intensity distribution
- Spectral line intensity ratio (391.4 nm N2+ / 337.1 nm N2) as proxy for net electric field
Limitations
- No biological/health outcomes assessed
- No quantitative values for applied voltage, frequency, pressure, or electric field reported in the abstract
- Sample size/number of experiments not stated
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "dielectric barrier surface glow discharge device",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Electric field distribution in dielectric barrier surface glow discharge",
"Optical emission intensity distribution",
"Spectral line intensity ratio (391.4 nm N2+ / 337.1 nm N2) as proxy for net electric field"
],
"main_findings": "Stable glow discharges in air at low pressure were obtained; the light signal showed one discharge pulse per half cycle of the applied voltage with asymmetry between positive and negative half cycles. Emission intensity was almost constant at locations with the same distance from the powered electrode and decreased with increasing distance. Using optical emission spectroscopy (391.4 nm/337.1 nm intensity ratio), the net electric field was inferred to be higher near the powered electrode than at the edge of the discharge.",
"effect_direction": "unclear",
"limitations": [
"No biological/health outcomes assessed",
"No quantitative values for applied voltage, frequency, pressure, or electric field reported in the abstract",
"Sample size/number of experiments not stated"
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"dielectric barrier discharge",
"surface glow discharge",
"electric field distribution",
"optical emission spectroscopy",
"photomultiplier tube",
"nitrogen spectral lines",
"N2+ first negative system",
"N2 second positive system"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: Not supplied
PubMed: 19248473
Related papers
- Electric field distribution and SAR inside a human eye exposed to Virtual Reality glasses 2018
- The effect of inter-electrode distance on the electric field distribution during transcutaneous lumbar spinal cord direct current stimulation. 2016
- Electric field analysis of breast tumor cells. 2011
- Reduction of implant RF heating through modification of transmit coil electric field. 2011
- Analysis of Electric Field in Real Rat Head Model during Transcranial Magnetic Stimulation. 2005
- Improving electric field distribution in a microwave heating device. 2000