Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners
← Research streamStatic magnetic field exposure profiles recorded during activities modelling cardiac MRI (42 scans across 1.5T, 3T, 7T scanners) differed significantly from those during head MRI. Most SEmf and TVEmf samples (up to the 95th percentile) were in ranges associat…
Study snapshot
Abstract
Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners Katarzyna Sklinda, Jolanta Karpowicz, Andrzej Stępniewski. Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners. Int J Environ Res Public Health. 2021 Dec 22;19(1):76. doi: 10.3390/ijerph19010076. Abstract (1) Background: It has been hypothesised that a significant increase in the use of cardiac magnetic resonance (CMR), for example, when examining COVID-19 convalescents using magnetic resonance imaging (MRI), has an influence the exposure profiles of medical personnel to static magnetic fields (STmf). (2) Methods: Static exposure to STmf (SEmf) was recorded during activities that modelled performing CMR by radiographers. The motion-induced time variability of that exposure (TVEmf) was calculated from SEmf samples. The results were compared with: (i) labour law requirements; (ii) the distribution of vertigo perception probability near MRI magnets; and (iii) the exposure profile when actually performing a head MRI. (3) Results: The exposure profiles of personnel managing 42 CMR scans (modelled using medium (1.5T), high (3T) and ultrahigh (7T) field scanners) were significantly different than when managing a head MRI. The majority of SEmf and TVEmf samples (up to the 95th percentile) were at low vertigo perception probability (SEmf < 500 mT, TVEmf < 600 mT/s), but a small fraction were at medium/high levels; (4) Conclusion: Even under the "normal working conditions" defined for SEmf (STmf < 2T) by labour legislation (Directive 2013/35/EC), increased CMR usage increases vertigo-related hazards experienced by MRI personnel (a re-evaluation of electromagnetic safety hazards is suggested in the case of these or similar changes in work organisation). Open access paper: mdpi.com
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Static magnetic field exposure profiles recorded during activities modelling cardiac MRI (42 scans across 1.5T, 3T, 7T scanners) differed significantly from those during head MRI. Most SEmf and TVEmf samples (up to the 95th percentile) were in ranges associated with low vertigo perception probability (SEmf < 500 mT; TVEmf < 600 mT/s), but a small fraction reached medium/high levels. The authors conclude that increased cardiac MRI usage may increase vertigo-related hazards for MRI personnel even under “normal working conditions” defined as STmf < 2T in Directive 2013/35/EC.
Outcomes measured
- Static exposure to static magnetic fields (SEmf)
- Motion-induced time variability of exposure (TVEmf)
- Vertigo perception probability distribution near MRI magnets
- Comparison to labour law requirements (Directive 2013/35/EC)
- Comparison of exposure profiles: cardiac MRI vs head MRI
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "static magnetic field",
"source": "MRI scanner (cardiac MRI; 1.5T, 3T, 7T)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Radiographers/medical personnel involved in cardiac MRI examinations",
"sample_size": 42,
"outcomes": [
"Static exposure to static magnetic fields (SEmf)",
"Motion-induced time variability of exposure (TVEmf)",
"Vertigo perception probability distribution near MRI magnets",
"Comparison to labour law requirements (Directive 2013/35/EC)",
"Comparison of exposure profiles: cardiac MRI vs head MRI"
],
"main_findings": "Static magnetic field exposure profiles recorded during activities modelling cardiac MRI (42 scans across 1.5T, 3T, 7T scanners) differed significantly from those during head MRI. Most SEmf and TVEmf samples (up to the 95th percentile) were in ranges associated with low vertigo perception probability (SEmf < 500 mT; TVEmf < 600 mT/s), but a small fraction reached medium/high levels. The authors conclude that increased cardiac MRI usage may increase vertigo-related hazards for MRI personnel even under “normal working conditions” defined as STmf < 2T in Directive 2013/35/EC.",
"effect_direction": "harm",
"limitations": [],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"cardiac MRI",
"MRI personnel",
"radiographers",
"static magnetic field",
"SEmf",
"TVEmf",
"vertigo",
"1.5T",
"3T",
"7T",
"Directive 2013/35/EC",
"occupational exposure"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.9,
"reason": "Assesses electromagnetic (static magnetic field) exposure profiles and vertigo-related hazards in MRI staff during work activities."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.3390/ijerph19010076
PubMed: Not supplied
Related papers
- Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands. 2013
- British Association of MR Radiographers (BAMRR) safety survey 2005: potential impact of European Union (EU) Physical Agents Directive (PAD) on electromagnetic fields (EMF). 2007
- Neurobiological effects and mechanisms of magnetic fields: a review from 2000 to 2023 2024
- Static magnetic fields as a factor in modification of tissue and cell structure: a review 2024
- Impact of weak radiofrequency and static magnetic fields on key signaling molecules, intracellular pH, membrane potential, and cell growth in HT-1080 fibrosarcoma cells 2023
- Zebrafish Larval Melanophores Respond to Electromagnetic Fields Exposure 2023