British Association of MR Radiographers (BAMRR) safety survey 2005: potential impact of European Union (EU) Physical Agents Directive (PAD) on electromagnetic fields (EMF).
← Research streamQuestionnaire responses suggested that staff presence in the magnet room occurs for an estimated 3% of MR examinations in the UK, and some of these examinations would be impossible without staff in the room, potentially requiring CT instead of MRI. The additi…
Study snapshot
Abstract
PURPOSE: To measure the potential impact on clinical MRI practice in the UK of the European Union (EU) Physical Agents Directive (PAD) on electromagnetic fields (EMF). There is evidence that the exposure limit values contained in the PAD will make it impossible for members of staff to stand close to the magnet during scanning; currently this is common practice in order to provide care and support for vulnerable patients. Interventional MR procedures will also be impossible. MATERIALS AND METHODS: Members of the British Association of MR Radiographers (BAMRR) were sent a questionnaire to assess the impact of the PAD and related safety issues. RESULTS: A total of 25% of responding sites have at least one sedation/general anesthesia (GA) session per week, while only 3% reported any interventional practice. A total of 29% of respondents reported that operators give a bolus injection by hand during contrast-enhanced magnetic resonance angiography (CE-MRA) scans. Overall it is estimated that 3% of all MR examinations in the UK are performed with a staff member in the magnet room. Some of these examinations would be impossible without staff in the room and it would be necessary for patients to have computed tomography (CT) instead of MRI. The additional radiation dose of substituting CT for MRI is estimated at 224 man-sievert per year. CONCLUSION: While the financial costs of implementing the PAD (EMF) are relatively low, the social costs are difficult to quantify but potentially more alarming.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Questionnaire responses suggested that staff presence in the magnet room occurs for an estimated 3% of MR examinations in the UK, and some of these examinations would be impossible without staff in the room, potentially requiring CT instead of MRI. The additional radiation dose from substituting CT for MRI was estimated at 224 man-sievert per year.
Outcomes measured
- Estimated proportion of MRI exams requiring staff presence in magnet room
- Reported frequency of sedation/general anesthesia sessions
- Reported interventional MRI practice
- Reported manual bolus injection during CE-MRA
- Estimated additional population radiation dose if CT substitutes for MRI (man-sievert/year)
- Perceived/estimated impact of EU Physical Agents Directive (EMF) on clinical MRI practice
Limitations
- Survey-based questionnaire; response rate and representativeness not reported in abstract
- Sample size not stated in abstract
- Estimates (e.g., % exams with staff in room; man-sievert/year) appear model-based and depend on assumptions not described in abstract
- Focuses on policy impact and practice implications rather than measured EMF exposure levels or health outcomes
View raw extracted JSON
{
"study_type": "cross_sectional",
"exposure": {
"band": null,
"source": "MRI occupational exposure (staff near magnet during scanning)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "UK MRI sites / members of the British Association of MR Radiographers (BAMRR)",
"sample_size": null,
"outcomes": [
"Estimated proportion of MRI exams requiring staff presence in magnet room",
"Reported frequency of sedation/general anesthesia sessions",
"Reported interventional MRI practice",
"Reported manual bolus injection during CE-MRA",
"Estimated additional population radiation dose if CT substitutes for MRI (man-sievert/year)",
"Perceived/estimated impact of EU Physical Agents Directive (EMF) on clinical MRI practice"
],
"main_findings": "Questionnaire responses suggested that staff presence in the magnet room occurs for an estimated 3% of MR examinations in the UK, and some of these examinations would be impossible without staff in the room, potentially requiring CT instead of MRI. The additional radiation dose from substituting CT for MRI was estimated at 224 man-sievert per year.",
"effect_direction": "unclear",
"limitations": [
"Survey-based questionnaire; response rate and representativeness not reported in abstract",
"Sample size not stated in abstract",
"Estimates (e.g., % exams with staff in room; man-sievert/year) appear model-based and depend on assumptions not described in abstract",
"Focuses on policy impact and practice implications rather than measured EMF exposure levels or health outcomes"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"MRI",
"radiographers",
"occupational exposure",
"electromagnetic fields",
"Physical Agents Directive",
"EU policy",
"sedation",
"general anesthesia",
"interventional MRI",
"CE-MRA",
"CT substitution",
"radiation dose"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.86,
"reason": "Assesses implications of EMF exposure limits for MRI staff practice (standing near magnet during scanning)."
},
{
"slug": "who-icnirp",
"weight": 0.3,
"reason": "Discusses exposure limit values in an EU directive; could relate to guideline/limit-setting context, though ICNIRP/WHO are not named in abstract."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1002/jmri.21154
PubMed: 17969163
Related papers
- Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands. 2013
- Occupational Electromagnetic Fields exposure in Magnetic Resonance Imaging systems - Preliminary results for the RF harmonic content. 2015
- A survey of the potential impact of the European Union Physical Agents Directive (EU PAD) on electromagnetic fields (EMF) on MRI research practice in the United Kingdom. 2008
- [Exposure of nurses to electromagnetic fields]. 2004
- Editorial: Neurological Illness and National Security: Lessons to Be Learned 2024
- Neuroimaging findings in US government personnel and their family members involved in anomalous 2024