Analyzing the SAR in Human Head Tissues under Different Exposure Scenarios
← Research streamSAR was measured in a standardized SAR lab using a phantom for RF-EMF sources at 900 MHz and 1800 MHz and used as reference for CST simulations on SAM and realistic human models. Simulations indicated higher SAR at 1800 MHz than 900 MHz, with highest-SAR rati…
Study snapshot
Abstract
Analyzing the SAR in Human Head Tissues under Different Exposure Scenarios Turgut A, Engiz BK. Analyzing the SAR in Human Head Tissues under Different Exposure Scenarios. Applied Sciences. 2023; 13(12):6971. doi.org Abstract This paper deals with the assessment of induced specific absorption rate (SAR) in various human models under different exposure scenarios, including both laboratory measurements and simulations. Firstly, SAR values were measured in a standardized SAR laboratory using a phantom for two radiofrequency electromagnetic field (RF- EMF) sources at 900 MHz and 1800 MHz. These laboratory measurements served as a reference for SAR calculations conducted on a specific anthropomorphic mannequin (SAM) using a computer simulation technology (CST) program, thus enabling the determination of antenna location and excitation signal levels for further evaluation. Subsequently, simulations were carried out with CST to evaluate average SAR for the head and for specific head tissues such as the brain, muscles, and fat. Realistic computational human models were also used alongside SAM in CST to explore the influence of gender, age, and tissue type on SAR. Various power levels representing low, moderate, and high RF-EMF exposure were applied to the human models to compare against basic restrictions and reference levels. The simulation results indicate significantly higher SAR values calculated for 1800 MHz compared with 900 MHz. The ratio of the highest SAR values at 1800 MHz to 900 MHz is approximately 1.70 for a baby, 2.59 for a child, and 2.84 for both adult female and adult male. While the SAR values for the brain, fat, muscle, and head are comparable at 900 MHz for the baby, the brain’s SAR value at 1800 MHz stands out significantly from the other tissues. In contrast with the baby, the difference in SAR values between 900 MHz and 1800 MHz is more pronounced for the child, adult female and adult male. The lowest SAR values at 900 MHz and 1800 MHz were obtained for brain tissue in all human models, while the head has the highest SAR value. The maximum SAR change ratio between the brain and the head is calculated to be 4.44 for the male at 1800 MHz. The results reveal that, although the applied electromagnetic field levels were below reference levels for general public local exposure, some local SAR values exceeded the International Commission of Non-Ionizing Radiation Protection’s basic restriction for the general public at certain power levels, particularly at 1800 MHz. The SAR analysis derived from this study is significant in understanding the impact of wireless technologies on health, establishing safety standards, guiding technology advancement, conducting risk assessments, and increasing public awareness. Open access paper: mdpi.com
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
SAR was measured in a standardized SAR lab using a phantom for RF-EMF sources at 900 MHz and 1800 MHz and used as reference for CST simulations on SAM and realistic human models. Simulations indicated higher SAR at 1800 MHz than 900 MHz, with highest-SAR ratios (1800/900) of ~1.70 (baby), 2.59 (child), and 2.84 (adult female and adult male). Although applied field levels were below general public local exposure reference levels, some local SAR values exceeded ICNIRP basic restrictions at certain power levels, particularly at 1800 MHz.
Outcomes measured
- Specific absorption rate (SAR) in head and head tissues (brain, muscle, fat)
- Comparison of SAR at 900 MHz vs 1800 MHz
- Comparison to ICNIRP basic restrictions and reference levels (general public local exposure)
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "RF",
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Computational human models (baby, child, adult female, adult male) and a standardized phantom/SAM mannequin for SAR assessment",
"sample_size": null,
"outcomes": [
"Specific absorption rate (SAR) in head and head tissues (brain, muscle, fat)",
"Comparison of SAR at 900 MHz vs 1800 MHz",
"Comparison to ICNIRP basic restrictions and reference levels (general public local exposure)"
],
"main_findings": "SAR was measured in a standardized SAR lab using a phantom for RF-EMF sources at 900 MHz and 1800 MHz and used as reference for CST simulations on SAM and realistic human models. Simulations indicated higher SAR at 1800 MHz than 900 MHz, with highest-SAR ratios (1800/900) of ~1.70 (baby), 2.59 (child), and 2.84 (adult female and adult male). Although applied field levels were below general public local exposure reference levels, some local SAR values exceeded ICNIRP basic restrictions at certain power levels, particularly at 1800 MHz.",
"effect_direction": "mixed",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"SAR",
"specific absorption rate",
"RF-EMF",
"900 MHz",
"1800 MHz",
"phantom",
"SAM",
"CST simulation",
"head tissues",
"brain",
"muscle",
"fat",
"ICNIRP basic restriction",
"reference levels"
],
"suggested_hubs": [
{
"slug": "who-icnirp",
"weight": 0.86,
"reason": "Abstract explicitly compares results to ICNIRP basic restrictions and reference levels for the general public."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.3390/app13126971
PubMed: Not supplied
Related papers
- Analysis of global DNA methylation changes in human keratinocytes immediately following exposure to a 2023
- Adverse effects of 900, 1800 and 2100 MHz radiofrequency radiation emitted from mobile phones on bone and skeletal muscle 2023
- Empirical study on specific absorption rate of head tissues due to induced heating of 4G cell phone radiation 2021
- Oxidative damage in the liver and brain of the rats exposed to frequency-dependent radiofrequency electromagnetic exposure: Biochemical and histopathological evidence 2021
- Electromagnetic radiation reduction using novel metamaterial for cellular applications 2021
- Temperature distribution and Specific Absorption Rate inside a child's head 2017