Induced electric currents in models of man and rodents from 60 Hz magnetic fields.

IEEE transactions on bio-medical engineering · 1994 · Unclear · Low evidence

← Research stream
UnclearLow evidencePaper 4317

Induced electric currents from 60 Hz magnetic fields were computed in realistic models of man, rat, and mouse using the impedance method. Results compared different species, tissue conductivities, and magnetic field orientations.

Study snapshot

PublicationIEEE transactions on bio-medical engineering · 1994
Study typeexposure_assessment
Reported directionUnclear
Evidence ratingLow

Abstract

Induced electric currents in models of man, rat and mouse from 60 Hz magnetic fields are computed using the impedance method. The models all have realistic shapes, and in the case of rodents, a homogeneous average tissue conductivity is assumed. The model of man is analyzed for two cases, a homogeneous average tissue conductivity and a heterogeneous model, both consisting of 1.3 cm cubical tissue cells whose conductivities are representative of the tissue within the cube. The results for various models and species, as well as different orientations of the magnetic field, are compared. The data presented are useful as the first step in dosimetry for 60 Hz magnetic fields, and for interspecies scaling of biological interactions related to the tissue induced electric currents.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeexposure_assessment
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposureELF · 0.06 MHz
Evidence strengthLowConfidence: 50% · Peer reviewed: yes

Main findings

Induced electric currents from 60 Hz magnetic fields were computed in realistic models of man, rat, and mouse using the impedance method. Results compared different species, tissue conductivities, and magnetic field orientations.

Outcomes measured

  • induced electric currents in tissue models

Limitations

  • Models assume homogeneous tissue conductivity for rodents
  • No direct biological effects measured, only dosimetry modeling
  • Limited to 60 Hz magnetic fields
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.06,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "induced electric currents in tissue models"
  ],
  "main_findings": "Induced electric currents from 60 Hz magnetic fields were computed in realistic models of man, rat, and mouse using the impedance method. Results compared different species, tissue conductivities, and magnetic field orientations.",
  "effect_direction": "unclear",
  "limitations": [
    "Models assume homogeneous tissue conductivity for rodents",
    "No direct biological effects measured, only dosimetry modeling",
    "Limited to 60 Hz magnetic fields"
  ],
  "evidence_strength": "low",
  "confidence": 0.5,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "60 Hz magnetic fields",
    "induced electric currents",
    "dosimetry",
    "impedance method",
    "tissue conductivity",
    "interspecies scaling"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1109/10.335839
PubMed: 8001990

Read the original paper →

Related papers

← Back to the Research Library