Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors.
← Research streamThe authors developed a wearable 3D orientation monitor combining miniature gravity and earth-magnetic field sensors for long-term ambulatory recordings. Calibration measurements indicated the method was fairly accurate and practically applicable for measurin…
Study snapshot
Abstract
OBJECTIVES: The study and diagnosis of movement disorders can be improved by monitoring body position simultaneously with the EMG. METHODS: We developed a monitor of the 3-dimensional (3D) orientation of body parts that can be applied in long-term ambulatory recordings in the daily life of a patient. The 3D sensor combines miniature sensors for earth's gravity and magnetism. It measures 60 x 50 x 10 mm and draws less than 1 mA of current from +/-5 V battery power. The non-horizontal direction of earth magnetism, as well as torque (pronation) of the body part, is corrected mathematically. RESULTS: This results in a measurement of the 3D orientation of a body part in terms of vertical inclination and horizontal azimuth. CONCLUSIONS: Calibration measurements indicate that this method is fairly accurate and practically applicable.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
The authors developed a wearable 3D orientation monitor combining miniature gravity and earth-magnetic field sensors for long-term ambulatory recordings. Calibration measurements indicated the method was fairly accurate and practically applicable for measuring vertical inclination and horizontal azimuth.
Outcomes measured
- 3D orientation/body position monitoring (vertical inclination, horizontal azimuth)
- Calibration accuracy/practical applicability
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "earth-magnetic field sensors",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"3D orientation/body position monitoring (vertical inclination, horizontal azimuth)",
"Calibration accuracy/practical applicability"
],
"main_findings": "The authors developed a wearable 3D orientation monitor combining miniature gravity and earth-magnetic field sensors for long-term ambulatory recordings. Calibration measurements indicated the method was fairly accurate and practically applicable for measuring vertical inclination and horizontal azimuth.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.66,
"peer_reviewed_likely": "yes",
"keywords": [
"body position",
"3D orientation",
"accelerometers",
"earth-magnetic field",
"magnetism sensors",
"ambulatory monitoring",
"movement disorders",
"EMG"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1016/s0924-980x(98)00053-8
PubMed: 10030679
Related papers
- Healthy disorders by WLAN-exposure 2022
- Artificial EMG (electromyogram) by WLAN exposure 2021
- Artificial EMG (Electromyogram) by WLAN-Exposure 2021
- Artificial EMG (electromyogram) by WLAN exposure 2021
- Artificial EMG (Electromyogram) by WLAN-Exposure 2021
- A wireless device for measuring hand-applied forces. 2004