Sanals (~1 μm) from rabbit primo vessels/nodes were observed under a low static magnetic field of 100 Oe. The average velocity of five sanals in saline solution, measured parallel and perpendicular to the applied field, was approximately 1.0 pixel/second in r…

Study snapshot

PublicationJournal of acupuncture and meridian studies · 2013
Study typeanimal
Reported directionMixed
Evidence ratingVery low

Abstract

The motion properties of the sanals of the primo vascular system were investigated under a low static magnetic field of 100 Oe. Sanals of about 1 μm were selected and separated from the primo vessels and nodes on a rabbit's organ surface. The average velocity of five sanals in a physiologic saline solution parallel and perpendicular to the direction of the applied magnetic field was approximately 1.0 pixel/second in random directions, which implies that the rotating motion of sanals with nuclei composed of DNA containing many inorganic magnetic elements such as manganese and cobalt is monotonically weakened by increasing an applied magnetic field.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionmixed
PopulationRabbit (sanals from primo vascular system on organ surface)
Sample size5
ExposureNot supplied
Evidence strengthVery lowConfidence: 62% · Peer reviewed: yes

Main findings

Sanals (~1 μm) from rabbit primo vessels/nodes were observed under a low static magnetic field of 100 Oe. The average velocity of five sanals in saline solution, measured parallel and perpendicular to the applied field, was approximately 1.0 pixel/second in random directions; the authors interpret this as rotating motion being monotonically weakened with increasing applied magnetic field.

Outcomes measured

  • Sanal motion/velocity in physiologic saline solution
  • Effect of magnetic field direction (parallel vs perpendicular) on motion

Limitations

  • Only five sanals were measured
  • Velocity reported in pixels/second (no physical unit conversion provided)
  • Exposure described as 100 Oe static magnetic field; details on field gradients, exposure setup, and any comparison condition are not provided in the abstract
  • Mechanistic explanation (DNA with inorganic magnetic elements) is speculative/interpretive in the abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": null,
    "source": "static magnetic field",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Rabbit (sanals from primo vascular system on organ surface)",
  "sample_size": 5,
  "outcomes": [
    "Sanal motion/velocity in physiologic saline solution",
    "Effect of magnetic field direction (parallel vs perpendicular) on motion"
  ],
  "main_findings": "Sanals (~1 μm) from rabbit primo vessels/nodes were observed under a low static magnetic field of 100 Oe. The average velocity of five sanals in saline solution, measured parallel and perpendicular to the applied field, was approximately 1.0 pixel/second in random directions; the authors interpret this as rotating motion being monotonically weakened with increasing applied magnetic field.",
  "effect_direction": "mixed",
  "limitations": [
    "Only five sanals were measured",
    "Velocity reported in pixels/second (no physical unit conversion provided)",
    "Exposure described as 100 Oe static magnetic field; details on field gradients, exposure setup, and any comparison condition are not provided in the abstract",
    "Mechanistic explanation (DNA with inorganic magnetic elements) is speculative/interpretive in the abstract"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.62,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "primo vascular system",
    "sanal",
    "static magnetic field",
    "100 Oe",
    "rabbit",
    "motion",
    "velocity"
  ],
  "suggested_hubs": [
    {
      "slug": "animal-studies",
      "weight": 0.78,
      "reason": "Rabbit-derived biological structures studied under a static magnetic field."
    }
  ]
}