Electronic response properties of carbon nanotubes in magnetic fields.
← Research streamUsing first-principles electronic structure methods, the authors computed magnetic shielding inside and outside achiral and chiral carbon nanotubes arising from electronic current densities induced by an external magnetic field. They report that in chiral nan…
Study snapshot
Abstract
Magnetic linear response properties for achiral and chiral carbon nanotubes were investigated with first-principles electronic structure methods. We have computed the magnetic shielding inside and outside the tubes originating from electronic current densities induced by the application of an external magnetic field. This electronic response of the nanotubes was analyzed for external magnetic fields both parallel and perpendicular to the tube axis. The magnetic screening would be experienced by guest molecules inside the tubes, measurable by NMR spectroscopy on isotopically labeled samples. Special attention is given to chiral nanotubes, in which longitudinal fields induce a non-zero longitudinal current density and thus tangential magnetic fields outside the tubes.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Using first-principles electronic structure methods, the authors computed magnetic shielding inside and outside achiral and chiral carbon nanotubes arising from electronic current densities induced by an external magnetic field. They report that in chiral nanotubes, longitudinal external fields induce a non-zero longitudinal current density and associated tangential magnetic fields outside the tubes; magnetic screening inside the tubes could be measurable by NMR on isotopically labeled samples.
Outcomes measured
- magnetic linear response properties
- magnetic shielding/screening inside and outside carbon nanotubes
- induced electronic current densities under external magnetic fields
- field-orientation dependence (parallel vs perpendicular to tube axis)
- tangential magnetic fields outside chiral nanotubes under longitudinal fields
Limitations
- Computational/first-principles study; no experimental exposure or health outcomes reported in the abstract.
- No quantitative exposure parameters (field strength, frequency) provided in the abstract.
- No biological population or sample size described.
View raw extracted JSON
{
"study_type": "in_vitro",
"exposure": {
"band": null,
"source": "other",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"magnetic linear response properties",
"magnetic shielding/screening inside and outside carbon nanotubes",
"induced electronic current densities under external magnetic fields",
"field-orientation dependence (parallel vs perpendicular to tube axis)",
"tangential magnetic fields outside chiral nanotubes under longitudinal fields"
],
"main_findings": "Using first-principles electronic structure methods, the authors computed magnetic shielding inside and outside achiral and chiral carbon nanotubes arising from electronic current densities induced by an external magnetic field. They report that in chiral nanotubes, longitudinal external fields induce a non-zero longitudinal current density and associated tangential magnetic fields outside the tubes; magnetic screening inside the tubes could be measurable by NMR on isotopically labeled samples.",
"effect_direction": "unclear",
"limitations": [
"Computational/first-principles study; no experimental exposure or health outcomes reported in the abstract.",
"No quantitative exposure parameters (field strength, frequency) provided in the abstract.",
"No biological population or sample size described."
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"carbon nanotubes",
"magnetic field",
"magnetic shielding",
"magnetic screening",
"electronic current density",
"chirality",
"first-principles",
"NMR"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1021/nn700147w
PubMed: 19206596
Related papers
- Electromagnetic Interference in the Modern Era: Concerns, Trends, and Nanomaterial-Based Solutions 2025
- Plasma-assembled carbon nanotubes: electric field-related effects. 2008
- Alignment of carbon nanotubes under low magnetic fields through attachment of magnetic nanoparticles. 2005
- Fast Disinfection of Escherichia coli Bacteria Using Carbon Nanotubes Interaction with Microwave Radiation. 2013
- Electric and magnetic field pollution in near substations and investigation of anxiety and depressive 2024
- No evidence for magnetic field effects on the behaviour of Drosophila 2023