Spatial and temporal assessment of radiofrequency electromagnetic fields emitted by smart meters and smart meter banks in urban environments.
← Research streamRF-EMF measurements around single AMI smart meters and banks (up to 81 meters) found maximum field levels at 0.3 m of 10–13 V/m for a single meter and 18–38 V/m for banks of 20–81 meters. Observed 6-min average duty cycles ranged from 0.01% (single meter) up …
Study snapshot
Abstract
This paper describes radiofrequency (RF) electromagnetic field (EMF) measurements in the vicinity of single and banks of advanced metering infrastructure (AMI) smart meters. The measurements were performed in a meter testing and distribution facility as well as in-situ at five urban locations. The measurements consisted of gauging the RF environment at the place of assessment, evaluating the worst-case electric-field levels at various positions around the assessed AMI meter configuration (spatial assessment), which ranged from a single meter to a bank of 81 m, and calculating the duty cycle of the system, i.e. the fraction of time that the AMI meters were actually transmitting (12-h temporal assessment). Both in-situ and in the meter facility, the maximum field levels at 0.3 m from the meter configurations were 10-13 V/m for a single meter and 18-38 V/m for meter banks with 20-81 m. Furthermore, 6-min average duty cycles of 0.01% (1 m) up to 13% (81-m bank) were observed. Next, two general statistical models (one for a single meter and one for a meter bank) were constructed to predict the electric-field strength as a function of distance to any configuration of the assessed AMI meters. For all scenarios, the measured exposure levels (at a minimum distance of 0.3 m) were well below the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the U.S. Federal Communications Commission (FCC), and the Institute of Electrical and Electronics Engineers (IEEE). Indeed, the worst-case time-average exposure level at a distance of 0.3 m from an AMI installation was 5.39% of the FCC/IEEE and 9.43% of the ICNIRP reference levels.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
RF-EMF measurements around single AMI smart meters and banks (up to 81 meters) found maximum field levels at 0.3 m of 10–13 V/m for a single meter and 18–38 V/m for banks of 20–81 meters. Observed 6-min average duty cycles ranged from 0.01% (single meter) up to 13% (81-meter bank). For all scenarios, measured exposure levels at a minimum distance of 0.3 m were reported to be well below ICNIRP, FCC, and IEEE limits; the worst-case time-average exposure at 0.3 m was 5.39% of FCC/IEEE and 9.43% of ICNIRP reference levels.
Outcomes measured
- Electric-field strength (V/m) around AMI smart meters and meter banks
- Duty cycle / fraction of time transmitting (temporal assessment)
- Comparison to ICNIRP, FCC, and IEEE maximum permissible exposure/reference levels
- Statistical models predicting electric-field strength as a function of distance
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "RF",
"source": "smart meter",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "12-h temporal assessment; 6-min average duty cycles reported"
},
"population": null,
"sample_size": null,
"outcomes": [
"Electric-field strength (V/m) around AMI smart meters and meter banks",
"Duty cycle / fraction of time transmitting (temporal assessment)",
"Comparison to ICNIRP, FCC, and IEEE maximum permissible exposure/reference levels",
"Statistical models predicting electric-field strength as a function of distance"
],
"main_findings": "RF-EMF measurements around single AMI smart meters and banks (up to 81 meters) found maximum field levels at 0.3 m of 10–13 V/m for a single meter and 18–38 V/m for banks of 20–81 meters. Observed 6-min average duty cycles ranged from 0.01% (single meter) up to 13% (81-meter bank). For all scenarios, measured exposure levels at a minimum distance of 0.3 m were reported to be well below ICNIRP, FCC, and IEEE limits; the worst-case time-average exposure at 0.3 m was 5.39% of FCC/IEEE and 9.43% of ICNIRP reference levels.",
"effect_direction": "no_effect",
"limitations": [],
"evidence_strength": "moderate",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"RF-EMF",
"smart meters",
"advanced metering infrastructure",
"AMI",
"meter banks",
"urban environments",
"electric-field strength",
"duty cycle",
"ICNIRP",
"FCC",
"IEEE",
"exposure assessment"
],
"suggested_hubs": [
{
"slug": "smart-meters",
"weight": 0.95,
"reason": "Direct RF-EMF measurements of AMI smart meters and smart meter banks, including duty cycle and comparison to exposure limits."
},
{
"slug": "who-icnirp",
"weight": 0.6,
"reason": "Explicit comparison of measured levels to ICNIRP reference levels."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1016/j.envres.2020.109196
PubMed: 32032814
Related papers
- Spatial and temporal assessment of radiofrequency electromagnetic fields emitted by smart meters and smart meter banks in urban environments 2020
- Community engagement programs on radiation and health: addressing public concerns. 2023
- Evaluation of Exposure to Radiofrequency Electromagnetic Fields from Smart Utility Meters operating at 2023
- Low Intensity Electromagnetic Fields Act via Voltage-Gated Calcium Channel (VGCC) Activation to Cause Very Early Onset Alzheimer's Disease: 18 Distinct Types of Evidence 2022
- Nordic Appeal: More Stringent Regulatory Framework on Microwave Radiation from Wireless Technologies is Needed - Stop Further Rollout of 5G 2023
- Exposure to EMF from smart utility meters in Great Britain; part I) laboratory measurements 2017