Functional brain MRI in patients complaining of EHS after long term exposure to EMF
← Research streamTen adult patients reporting EHS after long-term EMF exposure underwent resting-state fMRI; all 10 had abnormal fMRI findings, often described as hyperconnectivity of the anterior component of the default mode network in the medial orbitofrontal area. Regular…
Study snapshot
Abstract
Functional brain MRI in patients complaining of EHS after long term exposure to EMF Heuser G, Heuser SA. Functional brain MRI in patients complaining of electrohypersensitivity after long term exposure to electromagnetic fields. Rev Environ Health. 2017 Jul 5. Abstract INTRODUCTION: Ten adult patients with electromagnetic hypersensitivity underwent functional magnetic resonance imaging (fMRI) brain scans. All scans were abnormal with abnormalities which were consistent and similar. It is proposed that fMRI brain scans be used as a diagnostic aid for determining whether or not a patient has electromagnetic hypersensitivity. Over the years we have seen an increasing number of patients who had developed multi system complaints after long term repeated exposure to electromagnetic fields (EMFs). These complaints included headaches, intermittent cognitive and memory problems, intermittent disorientation, and also sensitivity to EMF exposure. Regular laboratory tests were within normal limits in these patients. The patients refused to be exposed to radioactivity. This of course ruled out positron emission tomography (PET) and single-photon emission computed tomography (SPECT) brain scanning. This is why we ordered fMRI brain scans on these patients. We hoped that we could document objective abnormalities in these patients who had often been labeled as psychiatric cases. MATERIALS AND METHODS: Ten patients first underwent a regular magnetic resonance imaging (MRI) brain scan, using a 3 Tesla Siemens Verio MRI open system. A functional MRI study was then performed in the resting state using the following sequences: A three-dimensional, T1-weighted, gradient-echo (MPRAGE) Resting state network. The echo-planar imaging (EPI) sequences for this resting state blood oxygenation level dependent (BOLD) scan were then post processed on a 3D workstation and the independent component analysis was performed separating out the various networks. Arterial spin labeling. Tractography and fractional anisotropy. RESULTS: All ten patients had abnormal functional MRI brain scans. The abnormality was often described as hyper connectivity of the anterior component of the default mode in the medial orbitofrontal area. Other abnormalities were usually found. Regular MRI studies of the brain were mostly unremarkable in these patients. CONCLUSION: We propose that functional MRI studies should become a diagnostic aid when evaluating a patient who claims electrohypersensitivity (EHS) and has otherwise normal studies. Interestingly, the differential diagnosis for the abnormalities seen on the fMRI includes head injury. It turns out that many of our patients indeed had a history of head injury which was then followed sometime later by the development of EHS. Many of our patients also had a history of exposure to potentially neurotoxic chemicals, especially mold. Head injury and neurotoxic chemical exposure may make a patient more vulnerable to develop EHS. ncbi.nlm.nih.gov
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Ten adult patients reporting EHS after long-term EMF exposure underwent resting-state fMRI; all 10 had abnormal fMRI findings, often described as hyperconnectivity of the anterior component of the default mode network in the medial orbitofrontal area. Regular (structural) MRI was mostly unremarkable.
Outcomes measured
- Resting-state functional MRI (fMRI) abnormalities
- Default mode network connectivity (anterior component; medial orbitofrontal area)
- Regular structural MRI findings
Limitations
- Very small sample size (n=10)
- No control/comparison group described
- Exposure characterization (type/frequency/intensity) not reported
- Potential confounding noted (history of head injury; exposure to neurotoxic chemicals such as mold)
- Observational design; diagnostic proposal rather than causal test
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": "long term repeated exposure (not further specified)"
},
"population": "Adults complaining of electrohypersensitivity (EHS)",
"sample_size": 10,
"outcomes": [
"Resting-state functional MRI (fMRI) abnormalities",
"Default mode network connectivity (anterior component; medial orbitofrontal area)",
"Regular structural MRI findings"
],
"main_findings": "Ten adult patients reporting EHS after long-term EMF exposure underwent resting-state fMRI; all 10 had abnormal fMRI findings, often described as hyperconnectivity of the anterior component of the default mode network in the medial orbitofrontal area. Regular (structural) MRI was mostly unremarkable.",
"effect_direction": "unclear",
"limitations": [
"Very small sample size (n=10)",
"No control/comparison group described",
"Exposure characterization (type/frequency/intensity) not reported",
"Potential confounding noted (history of head injury; exposure to neurotoxic chemicals such as mold)",
"Observational design; diagnostic proposal rather than causal test"
],
"evidence_strength": "very_low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"electrohypersensitivity",
"EHS",
"electromagnetic fields",
"EMF",
"functional MRI",
"fMRI",
"resting state",
"default mode network",
"hyperconnectivity",
"head injury",
"mold"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: Not supplied
PubMed: Not supplied
Related papers
- Functional brain MRI in patients complaining of EHS after long term exposure to EMF 2017
- Why electrohypersensitivity and related symptoms are caused by non-ionizing man-made electromagnetic fields: An overview and medical assessment 2022
- Electrohypersensitivity: what is belief and what is known? 2025
- Molecular biomarkers in Electrohypersensitivity and Multiple Chemical Sensitivity: How They Can 2024
- Wireless radiation and health: making the case for proteomics research of individual sensitivity 2024
- Prevalence of Migraine Disease in Electrohypersensitive Patients 2023