Effect of Radiofrequency Electromagnetic Fields on Thermal Sensitivity in the Rat

2020 · Mixed · Low evidence

← Research stream
MixedLow evidencePaper 1858

Compared with sham exposure, heat avoidance was significantly increased (+40%) in the 6 W/kg RF-EMF group. The RF-EMF effect on heat avoidance was abolished after NMDA treatment; in cage control and sham rats, NMDA (vs saline) significantly reduced latency to…

Study snapshot

Publicationmanual · 2020
Study typeanimal
Reported directionMixed
Evidence ratingLow

Abstract

Effect of Radiofrequency Electromagnetic Fields on Thermal Sensitivity in the Rat Nihal S Ouadah, Kelly Blazy, Anne-Sophie Villégier. Effect of Radiofrequency Electromagnetic Fields on Thermal Sensitivity in the Rat. Int J Environ Res Public Health. 2020 Oct 18;17(20):E7563. doi: 10.3390/ijerph17207563. Abstract The World Health Organization and the French Health Safety Agency (ANSES) recognize that the expressed pain and suffering of electromagnetic field hypersensitivity syndrome (EHS) people are a lived reality requiring daily life adaptations to cope. Mechanisms involving glutamatergic N-methyl d-aspartate (NMDA) receptors were not explored yet, despite their possible role in hypersensitivity to chemicals. Here, we hypothesized that radiofrequency electromagnetic field (RF-EMF) exposures may affect pain perception under a modulatory role played by the NMDA receptor. The rats were exposed to RF-EMF for four weeks (five times a week, at 0 (sham), 1.5 or 6 W/kg in restraint) or were cage controls (CC). Once a week, they received an NMDA or saline injection before being scored for their preference between two plates in the two-temperatures choice test: 50 °C (thermal nociception) versus 28 °C. Results in the CC and the sham rats indicated that latency to escape from heat was significantly reduced by -45% after NMDA, compared to saline treatment. Heat avoidance was significantly increased by +40% in the 6 W/kg, compared to the sham exposed groups. RF-EMF effect was abolished after NMDA treatment. In conclusion, heat avoidance was higher after high brain-averaged specific absorption rate, affording further support for possible effect of RF-EMF on pain perception. Further studies need to be performed to confirm these data. Open access paper: mdpi.com

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionmixed
PopulationRats
Sample sizeNot supplied
ExposureRF · 6 W/kg · 4 weeks (5 times/week)
Evidence strengthLowConfidence: 74% · Peer reviewed: yes

Main findings

Compared with sham exposure, heat avoidance was significantly increased (+40%) in the 6 W/kg RF-EMF group. The RF-EMF effect on heat avoidance was abolished after NMDA treatment; in cage control and sham rats, NMDA (vs saline) significantly reduced latency to escape from heat (-45%).

Outcomes measured

  • Thermal sensitivity/thermal nociception (two-temperatures choice test: 50 °C vs 28 °C)
  • Latency to escape from heat
  • Heat avoidance
  • Effect modification by NMDA receptor activation (NMDA vs saline injection)

Limitations

  • RF-EMF frequency not reported in abstract
  • Sample size not reported in abstract
  • Exposure described as brain-averaged SAR but details of dosimetry not provided in abstract
  • Authors note that further studies are needed to confirm the data
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "RF",
    "source": null,
    "frequency_mhz": null,
    "sar_wkg": 6,
    "duration": "4 weeks (5 times/week)"
  },
  "population": "Rats",
  "sample_size": null,
  "outcomes": [
    "Thermal sensitivity/thermal nociception (two-temperatures choice test: 50 °C vs 28 °C)",
    "Latency to escape from heat",
    "Heat avoidance",
    "Effect modification by NMDA receptor activation (NMDA vs saline injection)"
  ],
  "main_findings": "Compared with sham exposure, heat avoidance was significantly increased (+40%) in the 6 W/kg RF-EMF group. The RF-EMF effect on heat avoidance was abolished after NMDA treatment; in cage control and sham rats, NMDA (vs saline) significantly reduced latency to escape from heat (-45%).",
  "effect_direction": "mixed",
  "limitations": [
    "RF-EMF frequency not reported in abstract",
    "Sample size not reported in abstract",
    "Exposure described as brain-averaged SAR but details of dosimetry not provided in abstract",
    "Authors note that further studies are needed to confirm the data"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "RF-EMF",
    "radiofrequency electromagnetic fields",
    "thermal sensitivity",
    "pain perception",
    "thermal nociception",
    "NMDA receptor",
    "electromagnetic hypersensitivity",
    "SAR",
    "rat"
  ],
  "suggested_hubs": [
    {
      "slug": "mechanisms-nmda-glutamate",
      "weight": 0.78,
      "reason": "Study tests modulation of RF-EMF effects on pain perception via NMDA receptor activation."
    }
  ]
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.3390/ijerph17207563
PubMed: Not supplied

Read the original paper →

Related papers

← Back to the Research Library