Effect Exposure of Mobile Phone Radiation on Blood Parameters in Rats
← Research streamIn exposed rats, the study reports significant changes in multiple hematological indices versus controls. Reported effects include increased total WBC and lymphocyte percentage in the short-period 90 min condition, decreased neutrophil percentage in the long-…
Study snapshot
Abstract
Effect Exposure of Mobile Phone Radiation on Blood Parameters in Rats Al Abas, MAA, AL-Hakkak, ZMM (2021). Effect Exposure of Mobile Phone Radiation on Blood Parameters in Rats. Iraqi Journal of Science. 62(11): 4225–4231. doi: 10.24996/ijs.2021.62.11(SI).2. Abstract The aim of the research was to assess effects of short and long-period exposure to radiation from mobile phone on blood indices in experimental rats. In this study forty mature female rats were used; the animals were divided into two experimental group, each group consists of twenty animals. Short-period group of rats were exposed to cell phone radiation for different duration 30 m, 60 m, and 90 m per day for six weeks. Long-period group of rats were exposed to radiation from mobile phone for different duration 2h, 4h, and 6h per day for three months. The study noticed that there was significant (P≥0.05) elevation in total white blood cells and the study demonstrated significant increment (P≥0.05) in percentage of lymphocytes (71.1%) of rats which exposed to radiation from mobile phone for short-period in (90 minutes) compared to the control group (42.64%). While the study revealed that there was a significantly (P≥0.05) lower percentage of neutrophils (15.36%) in rats that were exposed to mobile phone radiation for long-period in (6 hours) compared with the control group (52.12%).The study recorded that there was a significant (P≥0.05) elevation in total red blood corpuscles and packed cell volume of rats exposed to radiation from mobile phone for short and long-period in different times compared with control. On the other hand, the research indicated that there was a significant (p≤0.05) decrement in mean corpuscles volume (MCV), mean corpuscle hemoglobin (MCH), mean corpuscle hemoglobin concentration and red blood cell distribution width standard deviation (RDW-SD) of rats to radiation from mobile phone for short and long-period in different times than control group. Conclusions It can be concluded that hematological parameters of rats were significantly affected after short and long-period exposure to radiation from mobile phone. The hematological analysis showed a significant elevation in values of white blood cells, lymphocytes, total red blood corpuscles and packed cell volume of rats after exposure to short and long-period to electromagnetic radiation from mobile phone. However, the study confirms that values of mean corpuscles volume and mean corpuscle hemoglobin concentration and red blood cell distribution width standard deviation were significantly decreased in rats after exposure to mobile phone electromagnetic radiation. Open access paper: ijs.uobaghdad.edu.iq
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In exposed rats, the study reports significant changes in multiple hematological indices versus controls. Reported effects include increased total WBC and lymphocyte percentage in the short-period 90 min condition, decreased neutrophil percentage in the long-period 6 h condition, increased total RBC and PCV across short and long exposure conditions, and decreased MCV, MCH, MCHC, and RDW-SD in exposed groups compared with controls.
Outcomes measured
- Total white blood cells (WBC)
- Lymphocyte percentage
- Neutrophil percentage
- Total red blood corpuscles (RBC)
- Packed cell volume (PCV)
- Mean corpuscular volume (MCV)
- Mean corpuscular hemoglobin (MCH)
- Mean corpuscular hemoglobin concentration (MCHC)
- Red blood cell distribution width standard deviation (RDW-SD)
Limitations
- Exposure characteristics not fully specified (e.g., frequency, SAR, distance from phone)
- Only mature female rats studied; generalizability to other sexes/species/humans unclear
- Statistical reporting appears inconsistent in abstract (e.g., 'significant (P≥0.05)')
- Control group details and randomization/blinding not described in abstract
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "RF",
"source": "mobile phone",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "Short-period: 30, 60, 90 min/day for 6 weeks; Long-period: 2, 4, 6 h/day for 3 months"
},
"population": "Mature female rats",
"sample_size": 40,
"outcomes": [
"Total white blood cells (WBC)",
"Lymphocyte percentage",
"Neutrophil percentage",
"Total red blood corpuscles (RBC)",
"Packed cell volume (PCV)",
"Mean corpuscular volume (MCV)",
"Mean corpuscular hemoglobin (MCH)",
"Mean corpuscular hemoglobin concentration (MCHC)",
"Red blood cell distribution width standard deviation (RDW-SD)"
],
"main_findings": "In exposed rats, the study reports significant changes in multiple hematological indices versus controls. Reported effects include increased total WBC and lymphocyte percentage in the short-period 90 min condition, decreased neutrophil percentage in the long-period 6 h condition, increased total RBC and PCV across short and long exposure conditions, and decreased MCV, MCH, MCHC, and RDW-SD in exposed groups compared with controls.",
"effect_direction": "harm",
"limitations": [
"Exposure characteristics not fully specified (e.g., frequency, SAR, distance from phone)",
"Only mature female rats studied; generalizability to other sexes/species/humans unclear",
"Statistical reporting appears inconsistent in abstract (e.g., 'significant (P≥0.05)')",
"Control group details and randomization/blinding not described in abstract"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"mobile phone radiation",
"electromagnetic radiation",
"rats",
"hematology",
"white blood cells",
"lymphocytes",
"neutrophils",
"red blood cells",
"packed cell volume",
"MCV",
"MCH",
"MCHC",
"RDW-SD"
],
"suggested_hubs": [
{
"slug": "mobile-phones",
"weight": 0.9,
"reason": "Exposure source is mobile phone radiation."
},
{
"slug": "animal-studies",
"weight": 0.85,
"reason": "Experimental study in rats assessing biological effects."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.24996/ijs.2021.62.11(si).2
PubMed: Not supplied
Related papers
- Histopathologic effects of mobile phone radiation exposure on the testes and sperm parameters: a 2025
- The toxic effect of mobile phone radiation on rabbit organs 2020
- Decreased Level of Plasma nesfatin-1 in Rats Exposed to Cell Phone Radiation Is Correlated With Thyroid Dysfunction, Oxidative Stress, and Apoptosis 2020
- Effect of cell phone radiation on neutrophil of mice 2019
- Monitoring of mice health, investigation of behavior, hematological parameters under the effect of an electromagnetic field 2019
- Enriched Environment Decreases Cognitive Impairment in Elderly Rats With Prenatal Mobile Phone Exposure 2020