Effects of medically generated electromagnetic interference from medical devices on cardiac implantable electronic devices: A review
← Research streamThe review describes evidence that electromagnetic interference from internal/external devices and during certain procedures can affect cardiac implantable electronic devices, including potentially inhibiting pacing in pacemakers and triggering shocks in ICDs…
Study snapshot
Abstract
Effects of medically generated electromagnetic interference from medical devices on cardiac implantable electronic devices: A review Barmore W, Patel H, Voong C, Tarallo C, Calkins JB Jr. Effects of medically generated electromagnetic interference from medical devices on cardiac implantable electronic devices: A review. World J Cardiol. 2022 Aug 26;14(8):446-453. doi: 10.4330/wjc.v14.i8.446. Abstract As cardiac implantable electronic devices (CIED) become more prevalent, it is important to acknowledge potential electromagnetic interference (EMI) from other sources, such as internal and external electronic devices and procedures and its effect on these devices. EMI from other sources can potentially inhibit pacing and trigger shocks in permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), respectively. This review analyzes potential EMI amongst CIED and left ventricular assist device, deep brain stimulators, spinal cord stimulators, transcutaneous electrical nerve stimulators, and throughout an array of procedures, such as endoscopy, bronchoscopy, and procedures involving electrocautery. Although there is evidence to support EMI from internal and external devices and during procedures, there is a lack of large multicenter studies, and, as a result, current management guidelines are based primarily on expert opinion and anecdotal experience. We aim to provide a general overview of PPM/ICD function, review documented EMI effect on these devices, and acknowledge current management of CIED interference Open access paper: ncbi.nlm.nih.gov
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
The review describes evidence that electromagnetic interference from internal/external devices and during certain procedures can affect cardiac implantable electronic devices, including potentially inhibiting pacing in pacemakers and triggering shocks in ICDs. It notes a lack of large multicenter studies and states that current management guidelines are based primarily on expert opinion and anecdotal experience.
Outcomes measured
- Electromagnetic interference (EMI) effects on CIED function
- Pacing inhibition in permanent pacemakers (PPM)
- Inappropriate triggering of shocks in implantable cardioverter defibrillators (ICD)
- Management/guidelines for CIED interference
Limitations
- Lack of large multicenter studies (as stated in the abstract)
- Management guidelines described as based primarily on expert opinion and anecdotal experience
View raw extracted JSON
{
"study_type": "review",
"exposure": {
"band": null,
"source": "medical devices and medical procedures causing electromagnetic interference (EMI)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "People with cardiac implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD)",
"sample_size": null,
"outcomes": [
"Electromagnetic interference (EMI) effects on CIED function",
"Pacing inhibition in permanent pacemakers (PPM)",
"Inappropriate triggering of shocks in implantable cardioverter defibrillators (ICD)",
"Management/guidelines for CIED interference"
],
"main_findings": "The review describes evidence that electromagnetic interference from internal/external devices and during certain procedures can affect cardiac implantable electronic devices, including potentially inhibiting pacing in pacemakers and triggering shocks in ICDs. It notes a lack of large multicenter studies and states that current management guidelines are based primarily on expert opinion and anecdotal experience.",
"effect_direction": "harm",
"limitations": [
"Lack of large multicenter studies (as stated in the abstract)",
"Management guidelines described as based primarily on expert opinion and anecdotal experience"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"electromagnetic interference",
"EMI",
"cardiac implantable electronic devices",
"CIED",
"pacemaker",
"permanent pacemaker",
"PPM",
"implantable cardioverter defibrillator",
"ICD",
"left ventricular assist device",
"deep brain stimulator",
"spinal cord stimulator",
"transcutaneous electrical nerve stimulator",
"endoscopy",
"bronchoscopy",
"electrocautery"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.2,
"reason": "Discusses EMI from medical devices/procedures affecting implanted cardiac devices; could be relevant to clinical/medical workplace exposure contexts, though occupational setting is not explicitly studied."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.4330/wjc.v14.i8.446
PubMed: Not supplied
Related papers
- Patients with pacemakers or defibrillators do not need to worry about e-Cars: An observational study 2019
- New-generation electronic appliances and cardiac implantable electronic devices: a systematic 2024
- Security millimetre wave body scanner safe for patients with leadless pacemakers or subcutaneous implantable cardioverter-defibrillators 2020
- Safety of smartwatches and their chargers in patients with cardiac implantable electronic devices 2020
- Safety evaluation of smart scales, smart watches, and smart rings with bioimpedance technology shows evidence of potential interference in cardiac implantable electronic devices 2023
- Interference thresholds for active implantable cardiovascular devices in occupational low-frequency electric and magnetic fields: a numerical and in vitro study 2022