Whole-body SAR measurements of millimeter-wave base station in reverberation chambers

International Journal of Microwave and Wireless Technologies · 2024 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 167

The paper presents a reverberation-chamber method to measure whole-body SAR of millimeter-wave base stations by comparing total radiated power with and without a phantom and using a chamber transfer function to exclude multipath-reflection absorption. The met…

Study snapshot

PublicationInternational Journal of Microwave and Wireless Technologies · 2024
Study typeexposure_assessment
Reported directionUnclear
Evidence ratingInsufficient

Abstract

Whole-body SAR measurements of millimeter-wave base station in reverberation chambers Eilers Bischoff J, Joshi P, Colombi D, Xu B, Törnevik C. Whole-body SAR measurements of millimeter- wave base station in reverberation chambers. International Journal of Microwave and Wireless Technologies. Published online 2024:1-6. doi:10.1017/S1759078724000515 Abstract This paper presents a method for measuring whole-body specific absorption rate (WBSAR) of millimeter- wave base stations (BSs) in a reverberation chamber (RC). The absorbed power in the phantom from the equipment under test (EUT) and hence WBSAR is determined as the difference between the total radiated power with and without the phantom. A chamber transfer function is determined and used to include only the absorption in the phantom due to direct illumination from the EUT, i.e., excluding absorption due to the RC multipath reflections. The measurement method was evaluated at 28 GHz using a horn antenna and a commercial massive multi-input–multi-output BS. The experimental results are in good agreement with simulations. The proposed method allows for measurements of WBSAR within 3 minutes, which is much shorter than traditional approaches. The method is suitable for compliance assessments of BS products with the International Commission on Non-Ionizing Radiation Protection 2020 electromagnetic field exposure guidelines, which extend the applicability of WBSAR as basic restrictions up to 300 GHz. doi.org

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeexposure_assessment
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposuremmWave · 28000 MHz · within 3 minutes (measurement time)
Evidence strengthInsufficientConfidence: 78% · Peer reviewed: yes

Main findings

The paper presents a reverberation-chamber method to measure whole-body SAR of millimeter-wave base stations by comparing total radiated power with and without a phantom and using a chamber transfer function to exclude multipath-reflection absorption. The method was evaluated at 28 GHz using a horn antenna and a commercial massive MIMO base station, with experimental results reported to be in good agreement with simulations, and enabling WBSAR measurements within 3 minutes.

Outcomes measured

  • Whole-body specific absorption rate (WBSAR) measurement method
  • Agreement between experimental results and simulations
  • Measurement time (speed)
  • Suitability for compliance assessment with ICNIRP 2020 guidelines up to 300 GHz
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "mmWave",
    "source": "base station",
    "frequency_mhz": 28000,
    "sar_wkg": null,
    "duration": "within 3 minutes (measurement time)"
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Whole-body specific absorption rate (WBSAR) measurement method",
    "Agreement between experimental results and simulations",
    "Measurement time (speed)",
    "Suitability for compliance assessment with ICNIRP 2020 guidelines up to 300 GHz"
  ],
  "main_findings": "The paper presents a reverberation-chamber method to measure whole-body SAR of millimeter-wave base stations by comparing total radiated power with and without a phantom and using a chamber transfer function to exclude multipath-reflection absorption. The method was evaluated at 28 GHz using a horn antenna and a commercial massive MIMO base station, with experimental results reported to be in good agreement with simulations, and enabling WBSAR measurements within 3 minutes.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "whole-body SAR",
    "WBSAR",
    "millimeter-wave",
    "mmWave",
    "base station",
    "massive MIMO",
    "reverberation chamber",
    "phantom",
    "28 GHz",
    "compliance assessment",
    "ICNIRP 2020",
    "transfer function"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.72,
      "reason": "Mentions ICNIRP 2020 EMF exposure guidelines and compliance assessment context."
    },
    {
      "slug": "5g-policy",
      "weight": 0.55,
      "reason": "Focuses on mmWave (28 GHz) base-station exposure assessment relevant to 5G deployments."
    }
  ]
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1017/s1759078724000515
PubMed: Not supplied

Read the original paper →

Related papers