A comparison of the efficacy of mechanical, chemical, and microwave radiation methods in disinfecting complete dentures.

Dental research journal · 2017 · Benefit · Low evidence

← Research stream
BenefitLow evidencePaper 6612

In contaminated dentures, microwave irradiation (650 W for 3 min), 2% glutaraldehyde, and Corega tablets showed no evidence of bacterial growth at 48 h and no turbidity after 7 days, compared with positive controls (P < 0.001). Brushing showed bacterial growt…

Study snapshot

PublicationDental research journal · 2017
Study typein_vitro
Reported directionBenefit
Evidence ratingLow

Abstract

BACKGROUND: Poor denture hygiene can be a potential source of pathogens. The aim of this study was to compare the efficacy of microwave radiation with that of chemical and mechanical techniques in disinfecting complete dentures contaminated with and . MATERIALS AND METHODS: Seventy-two sterilized mandibular dentures were separately contaminated with ( = 32) and ( = 32) and then incubated at 37°C for 48 h. The contaminated dentures were disinfected as follows: chemical disinfection with Corega tablets; chemical disinfection with 2% glutaraldehyde; mechanical disinfection by brushing the denture; and physical disinfection by 650-W microwaves irradiation for 3 min with six samples in each subgroup. Six dentures served as negative control group, and six contaminated dentures with no disinfection served as the positive control group. 10-10 dilutions were cultured in the nutrient agar, and the colonies were counted after incubation at 37°C for 48 h. To evaluate the lasting time of disinfection, the containers with nutrient agar and dentures were stored for 7 days at 37°C to evaluate turbidity. Data were analyzed using Kruskal-Wallis and Mann-Whitney U-test (α = 0.05). RESULTS: There was no evidence of bacterial growth in 48 h and turbidity after 7 days of incubation of dentures disinfected by microwaves, glutaraldehyde, and Corega tablets, which was statistically significant compared to the positive controls ( < 0.001). In mechanically disinfected dentures (brushing), bacterial growth was detected after 48 h which was statistically significant compared to the positive controls ( < 0.001) and turbidity was seen in all the nutrient agar plates. CONCLUSION: Microwave iradiation, 2% glutaraldehyde, and Corega tablets disinfected complete dentures contaminated with and which lasted for a long and a short terms.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typein_vitro
Effect directionbenefit
PopulationNot supplied
Sample size72
Exposure3 min
Evidence strengthLowConfidence: 74% · Peer reviewed: yes

Main findings

In contaminated dentures, microwave irradiation (650 W for 3 min), 2% glutaraldehyde, and Corega tablets showed no evidence of bacterial growth at 48 h and no turbidity after 7 days, compared with positive controls (P < 0.001). Brushing showed bacterial growth at 48 h and turbidity in all plates.

Outcomes measured

  • Bacterial growth/colony counts after 48 h incubation
  • Turbidity after 7 days (lasting time of disinfection)

Limitations

  • In vitro denture model; may not reflect real-world use conditions
  • Microwave exposure characterized by power and time only; frequency and dosimetry not reported
  • Small subgroup sizes (six samples per subgroup)
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": null,
    "source": "microwave disinfection (microwave oven irradiation)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "3 min"
  },
  "population": null,
  "sample_size": 72,
  "outcomes": [
    "Bacterial growth/colony counts after 48 h incubation",
    "Turbidity after 7 days (lasting time of disinfection)"
  ],
  "main_findings": "In contaminated dentures, microwave irradiation (650 W for 3 min), 2% glutaraldehyde, and Corega tablets showed no evidence of bacterial growth at 48 h and no turbidity after 7 days, compared with positive controls (P < 0.001). Brushing showed bacterial growth at 48 h and turbidity in all plates.",
  "effect_direction": "benefit",
  "limitations": [
    "In vitro denture model; may not reflect real-world use conditions",
    "Microwave exposure characterized by power and time only; frequency and dosimetry not reported",
    "Small subgroup sizes (six samples per subgroup)"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave irradiation",
    "denture disinfection",
    "glutaraldehyde",
    "Corega tablets",
    "mechanical brushing",
    "Candida",
    "Staphylococcus"
  ],