Overwhelming Thermomechanical Motion with Microwave Radiation Pressure Shot Noise.

Physical review letters · 2016 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 6598

In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can ov…

Study snapshot

PublicationPhysical review letters · 2016
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

We measure the fundamental noise processes associated with a continuous linear position measurement of a micromechanical membrane incorporated in a microwave cavity optomechanical circuit. We observe the trade-off between the two fundamental sources of noise that enforce the standard quantum limit: the measurement imprecision and radiation pressure backaction from photon shot noise. We demonstrate that the quantum backaction of the measurement can overwhelm the intrinsic thermal motion by 24 dB, entering a new regime for cavity optomechanical systems.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
Exposuremicrowave
Evidence strengthInsufficientConfidence: 74% · Peer reviewed: yes

Main findings

In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.

Outcomes measured

  • measurement imprecision noise
  • radiation pressure backaction (photon shot noise)
  • thermomechanical (intrinsic thermal) motion
  • standard quantum limit trade-off
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "microwave",
    "source": "microwave cavity optomechanical circuit",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "measurement imprecision noise",
    "radiation pressure backaction (photon shot noise)",
    "thermomechanical (intrinsic thermal) motion",
    "standard quantum limit trade-off"
  ],
  "main_findings": "In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave",
    "cavity optomechanics",
    "micromechanical membrane",
    "radiation pressure",
    "photon shot noise",
    "quantum backaction",
    "standard quantum limit",
    "thermomechanical motion",
    "position measurement",
    "noise processes"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1103/physrevlett.116.013602
PubMed: 26799018

Read the original paper →

Related papers

← Back to the Research Library