Overwhelming Thermomechanical Motion with Microwave Radiation Pressure Shot Noise.
← Research streamIn a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can ov…
Study snapshot
Abstract
We measure the fundamental noise processes associated with a continuous linear position measurement of a micromechanical membrane incorporated in a microwave cavity optomechanical circuit. We observe the trade-off between the two fundamental sources of noise that enforce the standard quantum limit: the measurement imprecision and radiation pressure backaction from photon shot noise. We demonstrate that the quantum backaction of the measurement can overwhelm the intrinsic thermal motion by 24 dB, entering a new regime for cavity optomechanical systems.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.
Outcomes measured
- measurement imprecision noise
- radiation pressure backaction (photon shot noise)
- thermomechanical (intrinsic thermal) motion
- standard quantum limit trade-off
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "microwave",
"source": "microwave cavity optomechanical circuit",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"measurement imprecision noise",
"radiation pressure backaction (photon shot noise)",
"thermomechanical (intrinsic thermal) motion",
"standard quantum limit trade-off"
],
"main_findings": "In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"microwave",
"cavity optomechanics",
"micromechanical membrane",
"radiation pressure",
"photon shot noise",
"quantum backaction",
"standard quantum limit",
"thermomechanical motion",
"position measurement",
"noise processes"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1103/physrevlett.116.013602
PubMed: 26799018
Related papers
- Published since 2024 (Volume 3) 2024
- Impact of specific electromagnetic radiation on wakefulness in mice 2024
- Does Microwave Exposure at Different Doses in the Pre/Postnatal Period Affect Growing Rat Bone 2024
- A broadband multi-frequency microwave combined biological exposure setup 2024
- Acute exposure of microwave impairs attention process by activating microglial inflammation 2024
- Compound exposure of 2.8 GHz and 9.3 GHz microwave causes learning and memory impairment in 2025