Design idea for a microwave energy coupler in biomedical field.

Journal of biomedical engineering · 1983 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 5946

A new microstrip transmission-line based structure is proposed and assessed for a direct-contact microwave applicator. The design is described as having very small size and weight, good matching, and a sufficiently defined and small irradiated value.

Study snapshot

PublicationJournal of biomedical engineering · 1983
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

The use of microwave radiation for biomedical purposes has been increasing in recent years. Among the most important applications are localized hyperthermia, noninvasive diagnosis and monitoring of cardiovascular system parameters and characterization of biological tissues. For all these purposes the design of suitable electromagnetic (e.m.) energy couplers is of fundamental importance. In this paper a new structure is suggested and assessed for a direct contact microwave applicator. The proposed radiating system is obtained using the microstrip transmission lines technique and its principal characteristics are very small sizes and weight, together with good matching and sufficiently defined and small irradiated value.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
Exposuremicrowave
Evidence strengthInsufficientConfidence: 66% · Peer reviewed: yes

Main findings

A new microstrip transmission-line based structure is proposed and assessed for a direct-contact microwave applicator. The design is described as having very small size and weight, good matching, and a sufficiently defined and small irradiated value.

Outcomes measured

  • Design/assessment of an electromagnetic energy coupler (microwave applicator) for biomedical uses
  • Device characteristics (size/weight, matching, irradiated area/value)
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "microwave",
    "source": "direct contact microwave applicator",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Design/assessment of an electromagnetic energy coupler (microwave applicator) for biomedical uses",
    "Device characteristics (size/weight, matching, irradiated area/value)"
  ],
  "main_findings": "A new microstrip transmission-line based structure is proposed and assessed for a direct-contact microwave applicator. The design is described as having very small size and weight, good matching, and a sufficiently defined and small irradiated value.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.66,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "microwave radiation",
    "biomedical applications",
    "localized hyperthermia",
    "noninvasive diagnosis",
    "cardiovascular monitoring",
    "tissue characterization",
    "electromagnetic energy coupler",
    "direct contact applicator",
    "microstrip transmission lines"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1016/0141-5425(83)90103-6
PubMed: 6887826

Read the original paper →

Related papers

← Back to the Research Library