Personal digital assistant (PDA) cell phone units produce elevated extremely-low frequency electromagnetic field emissions.
← Research streamELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from…
Study snapshot
Abstract
Initial tests indicate that personal and occupational use of personal digital assistants (PDAs or palm-held wireless units) produce high intensity bursts of extremely-low frequency electromagnetic fields (ELF-EMF). These emissions could result in comparatively high ELF-EMF exposure in persons that carry a PDA close to the body (i.e., in a pocket or on a belt); or held to the head for cell phone conversations. ELF-EMF emissions of 10 microT were recorded on PDAs during normal office use over a 24 h test period. Results of ELF-EMF measurements show that email transmit and receive functions produce rapid, short-duration ELF-EMF spikes in the 2-10 microT range, each lasting several seconds to over a minute apparently depending on file download size. Some units produced spikes as high as 30-60 microT during email activities. Cell phone activity on PDAs produced continuously elevated ELF-EMF readings in the 0.5-1 microT range, as opposed to the rapid spiking pattern for email receipt and transmission. Switching the PDA unit from "OFF" to "ON" position resulted in single ELF-EMF pulses of over 90 microT on two units. Email downloads into the PDA can occur randomly throughout the day and night when the unit is "ON"; thus the user who wears the PDA may be receiving high-intensity ELF-EMF pulses throughout the day and night. The frequency of email traffic on the PDA, and the power switching unit (battery unit) may affect the frequency and intensity of ELF-EMF emissions.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.
Outcomes measured
- ELF-EMF emission levels (microT) during PDA normal office use
- ELF-EMF spikes during email transmit/receive
- ELF-EMF levels during cell phone activity
- ELF-EMF pulses when switching from OFF to ON
Limitations
- Population and health outcomes were not assessed (emissions/exposure characterization only).
- Sample size and number of PDA units tested are not reported in the abstract.
- Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract.
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "ELF",
"source": "personal digital assistant (PDA) / palm-held wireless unit with cell phone and email functions",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "24 h test period; spikes lasting several seconds to over a minute"
},
"population": null,
"sample_size": null,
"outcomes": [
"ELF-EMF emission levels (microT) during PDA normal office use",
"ELF-EMF spikes during email transmit/receive",
"ELF-EMF levels during cell phone activity",
"ELF-EMF pulses when switching from OFF to ON"
],
"main_findings": "ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.",
"effect_direction": "unclear",
"limitations": [
"Population and health outcomes were not assessed (emissions/exposure characterization only).",
"Sample size and number of PDA units tested are not reported in the abstract.",
"Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract."
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"PDA",
"personal digital assistant",
"palm-held wireless unit",
"ELF-EMF",
"extremely-low frequency",
"microtesla",
"email transmit",
"email receive",
"cell phone activity",
"power switching",
"battery unit",
"exposure assessment"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.42,
"reason": "Abstract mentions personal and occupational use and measurements during normal office use."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1002/bem.20315
PubMed: 17357117
Related papers
- Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication. 2013
- A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies. 2005
- [Medical image transfer for emergency care utilizing internet and mobile phone]. 2002
- Validity and reliability of a dietary assessment method: the application of a digital camera with a mobile phone card attachment. 2002
- Cellular and molecular effects of non-ionizing electromagnetic fields 2023
- Neurological effects of static and extremely-low frequency electromagnetic fields (Review) 2022