Theta-gamma coupling in hippocampus during working memory deficits induced by low frequency electromagnetic field exposure.

Physiology & behavior · 2017 · Harm · Low evidence

← Research stream
HarmLow evidencePaper 4918

Mice exposed to 50 Hz, 1 mT EMF showed a significantly decreased correct choice rate in a Y-maze working memory task after 3 days of exposure, accompanied by a decline in hippocampal firing rate. From day 3, theta (4–12 Hz) and low-gamma (30–60 Hz) power befo…

Study snapshot

PublicationPhysiology & behavior · 2017
Study typeanimal
Reported directionHarm
Evidence ratingLow

Abstract

The dramatically increased use of electricity is raising major concerns as to the consequences of the interaction between electromagnetic field (EMF) and neurobiology. The aim of this study is to investigate the effects of magnetic field on working memory in the hippocampal region by analyzing local field potentials (LFPs) and spikes pattern in vivo. In present study, mice were exposed to EMF (50Hz, 1mT), static magnetic field (SMF, 1mT), or placed in the exposure tube but without EMF exposure (SHAM), respectively. During the exposure for 7 consecutive days, mice were subjected to perform working memory (WM) tasks in Y-maze, and multichannel electrophysiology signals from hippocampus of mice were recorded during the test, from which LFPs, spike firing rates, band power at different frequencies, and theta-gamma modulation index (MI) were analyzed in details. From our results, correct choice rate during WM task was found significantly decreased in EMF group after 3-day exposure, which was consistent with noticeable decline in firing rate. Starting from Day 3 after EMF exposure, the power of theta (4-12Hz) and gamma (LG, 30-60Hz) before reference point (RP) in Y-maze were also found to be descending, together with decrease of oscillatory activities of theta and gamma frequencies. The results indicated that MI between theta and gamma could play a significant role in modulating the spikes discharge and encoding WM. Therefore, the analysis of theta-gamma coupling and its oscillation strength may provide a new perspective for mechanistic investigation of EMF-induced WM deficits.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeanimal
Effect directionharm
PopulationMice
Sample sizeNot supplied
ExposureELF · 5e-05 MHz · 7 consecutive days
Evidence strengthLowConfidence: 78% · Peer reviewed: yes

Main findings

Mice exposed to 50 Hz, 1 mT EMF showed a significantly decreased correct choice rate in a Y-maze working memory task after 3 days of exposure, accompanied by a decline in hippocampal firing rate. From day 3, theta (4–12 Hz) and low-gamma (30–60 Hz) power before a reference point in the Y-maze were reported to decrease, along with reduced theta/gamma oscillatory activity; the authors suggest theta–gamma coupling (MI) is relevant to EMF-associated working memory deficits.

Outcomes measured

  • Working memory performance (Y-maze correct choice rate)
  • Hippocampal electrophysiology (local field potentials, spike firing rates)
  • Theta band power (4–12 Hz)
  • Gamma band power (30–60 Hz)
  • Theta–gamma coupling/modulation index (MI)

Limitations

  • Sample size not reported in the abstract
  • Details of randomization/blinding not reported in the abstract
  • Exposure characterization limited to frequency and magnetic flux density (no dosimetry/SAR reported)
  • Results summarized without quantitative effect sizes in the abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": "other",
    "frequency_mhz": 5e-05,
    "sar_wkg": null,
    "duration": "7 consecutive days"
  },
  "population": "Mice",
  "sample_size": null,
  "outcomes": [
    "Working memory performance (Y-maze correct choice rate)",
    "Hippocampal electrophysiology (local field potentials, spike firing rates)",
    "Theta band power (4–12 Hz)",
    "Gamma band power (30–60 Hz)",
    "Theta–gamma coupling/modulation index (MI)"
  ],
  "main_findings": "Mice exposed to 50 Hz, 1 mT EMF showed a significantly decreased correct choice rate in a Y-maze working memory task after 3 days of exposure, accompanied by a decline in hippocampal firing rate. From day 3, theta (4–12 Hz) and low-gamma (30–60 Hz) power before a reference point in the Y-maze were reported to decrease, along with reduced theta/gamma oscillatory activity; the authors suggest theta–gamma coupling (MI) is relevant to EMF-associated working memory deficits.",
  "effect_direction": "harm",
  "limitations": [
    "Sample size not reported in the abstract",
    "Details of randomization/blinding not reported in the abstract",
    "Exposure characterization limited to frequency and magnetic flux density (no dosimetry/SAR reported)",
    "Results summarized without quantitative effect sizes in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low frequency",
    "ELF-EMF",
    "50 Hz",
    "1 mT",
    "static magnetic field",
    "hippocampus",
    "working memory",
    "Y-maze",
    "local field potentials",
    "spike firing rate",
    "theta",
    "gamma",
    "theta-gamma coupling",
    "modulation index"
  ],
  "suggested_hubs": [
    {
      "slug": "elf-emf",
      "weight": 0.9,
      "reason": "Animal study of 50 Hz (ELF) magnetic field exposure and neurobehavioral/neurophysiological outcomes."
    }
  ]
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1016/j.physbeh.2017.05.033
PubMed: 28579129

Read the original paper →

Related papers

← Back to the Research Library