Radiofrequency exposure in the Neonatal Medium Care Unit.
← Research streamSpot measurements had a mean field strength of 1.51±0.48 V/m, with higher values near the window and near the evaluated incubator. Long-term measurements inside the incubator over 17 h had a mean of 0.81±0.07 V/m and a maximum of 1.58 V/m; night-time values w…
Study snapshot
Abstract
The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit's incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17h was 0.81 (±0.07)V/m and the maximum value was 1.58V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Spot measurements had a mean field strength of 1.51±0.48 V/m, with higher values near the window and near the evaluated incubator. Long-term measurements inside the incubator over 17 h had a mean of 0.81±0.07 V/m and a maximum of 1.58 V/m; night-time values were higher than daytime values.
Outcomes measured
- RF-EMF electric field strength (V/m) in neonatal medium care unit
- RF-EMF electric field strength (V/m) inside incubators
- Day vs night RF-EMF levels
- Spatial variation (e.g., proximity to window/incubator)
Limitations
- Frequency bands/sources contributing to measured RF-EMF are not specified in the abstract.
- Number of measurement locations/incubators and measurement protocol details are not provided in the abstract.
- No health outcomes were measured; the study characterizes exposure only.
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "RF",
"source": "neonatal care unit environment/incubator",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "spot measurements and long-term measurements over 17 h"
},
"population": "Premature/newborn infants in a Neonatal Medium Care Unit (incubator environment)",
"sample_size": null,
"outcomes": [
"RF-EMF electric field strength (V/m) in neonatal medium care unit",
"RF-EMF electric field strength (V/m) inside incubators",
"Day vs night RF-EMF levels",
"Spatial variation (e.g., proximity to window/incubator)"
],
"main_findings": "Spot measurements had a mean field strength of 1.51±0.48 V/m, with higher values near the window and near the evaluated incubator. Long-term measurements inside the incubator over 17 h had a mean of 0.81±0.07 V/m and a maximum of 1.58 V/m; night-time values were higher than daytime values.",
"effect_direction": "unclear",
"limitations": [
"Frequency bands/sources contributing to measured RF-EMF are not specified in the abstract.",
"Number of measurement locations/incubators and measurement protocol details are not provided in the abstract.",
"No health outcomes were measured; the study characterizes exposure only."
],
"evidence_strength": "insufficient",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"keywords": [
"RF-EMF",
"radiofrequency",
"electromagnetic fields",
"exposure assessment",
"neonatal medium care unit",
"incubator",
"dosimeter",
"electric field strength",
"V/m",
"night vs day"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.3,
"reason": "Measurements were conducted in a clinical care unit environment where staff and patients may be exposed, though the focus is on incubator exposure."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1016/j.envres.2016.09.019
PubMed: 27741450
Related papers
- Radiofrequency exposure in the Neonatal Medium Care Unit 2017
- RF-EMF Exposure for sub-6GHz 5G NR Massive MIMO Base Station 2022
- A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations 2017
- Machine Learning Approach for Ground-Level Estimation of Electromagnetic Radiation in the Near Field of 5G Base Stations 2025
- [Assessment of electromagnetic fields intensity emitted by cellular phone base stations in surrounding flats--a preliminary study]. 2006
- The pattern of the electromagnetic field emitted by mobile phones in motor vehicle driving simulators. 2013