Magnetic field effects-polarization-resonant synchronous fluorescence spectrometry for simultaneous analysis of polynuclear aromatic hydrocarbons in mixtures.

Talanta · 1995 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 4288

Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarb…

Study snapshot

PublicationTalanta · 1995
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

The level and undulation of scattered light can be effectively suppressed by magnetic field effects-polarization-resonant synchronous fluorescence spectrometry. The established technique was used for simultaneous determination of a sample mixture containing fluorene, acenaphthene, anthracene, benzo-[a]-pyrene (B-[a]-P) and perylene. The detection limits were 0.23, 7.90, 0.13, 1.10, 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, B-[a]-P and perylene, respectively. The relative standard deviations were less than 5%.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposureNot supplied
Evidence strengthInsufficientConfidence: 74% · Peer reviewed: yes

Main findings

Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.

Outcomes measured

  • Suppression of scattered light level and undulation in fluorescence spectrometry
  • Detection limits for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene
  • Relative standard deviation (precision)

Limitations

  • No biological or health outcomes assessed (analytical chemistry method).
  • Magnetic field parameters (strength, frequency) not reported in the abstract.
  • Sample type and number of measurements/replicates not stated.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "magnetic field (instrumental/analytical method)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Suppression of scattered light level and undulation in fluorescence spectrometry",
    "Detection limits for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene",
    "Relative standard deviation (precision)"
  ],
  "main_findings": "Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.",
  "effect_direction": "unclear",
  "limitations": [
    "No biological or health outcomes assessed (analytical chemistry method).",
    "Magnetic field parameters (strength, frequency) not reported in the abstract.",
    "Sample type and number of measurements/replicates not stated."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "magnetic field effects",
    "polarization",
    "resonant synchronous fluorescence spectrometry",
    "scattered light suppression",
    "polynuclear aromatic hydrocarbons",
    "fluorene",
    "acenaphthene",
    "anthracene",
    "benzo[a]pyrene",
    "perylene",
    "detection limit",
    "precision"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1016/0039-9140(95)01629-5
PubMed: 18966418

Read the original paper →

Related papers

← Back to the Research Library