An SRRC elliptically polarizing undulator prototype to examine mechanical design feasibility and magnetic field performance.
← Research streamA 1 m long Sasaki-type elliptically polarizing undulator prototype (5.6 cm period) was used to describe magnetic field characteristics under various phase shifts and gap motions. Sources of field errors were analyzed and correction procedures (block position …
Study snapshot
Abstract
In this work, a 1 m long Sasaki-type elliptically polarizing undulator (EPU) prototype with 5.6 cm period length is used to examine the mechanical design feasibility as well as magnetic field performance. The magnetic field characteristics of the EPU5.6 prototype at various phase shifts and gap motion are described. The field errors from mechanical tolerances, magnet block errors, end field effects and phase/gap motion effects are analysed. The procedures related to correcting the field with the block position tuning, iron shimming and the trim blocks at both ends are outlined.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
A 1 m long Sasaki-type elliptically polarizing undulator prototype (5.6 cm period) was used to describe magnetic field characteristics under various phase shifts and gap motions. Sources of field errors were analyzed and correction procedures (block position tuning, iron shimming, trim blocks) were outlined.
Outcomes measured
- mechanical design feasibility
- magnetic field performance/characteristics
- field errors (mechanical tolerances, magnet block errors, end field effects, phase/gap motion effects)
- field correction procedures (block position tuning, iron shimming, trim blocks)
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "elliptically polarizing undulator (synchrotron insertion device)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"mechanical design feasibility",
"magnetic field performance/characteristics",
"field errors (mechanical tolerances, magnet block errors, end field effects, phase/gap motion effects)",
"field correction procedures (block position tuning, iron shimming, trim blocks)"
],
"main_findings": "A 1 m long Sasaki-type elliptically polarizing undulator prototype (5.6 cm period) was used to describe magnetic field characteristics under various phase shifts and gap motions. Sources of field errors were analyzed and correction procedures (block position tuning, iron shimming, trim blocks) were outlined.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"elliptically polarizing undulator",
"Sasaki-type",
"magnetic field characteristics",
"field errors",
"mechanical tolerances",
"phase shift",
"gap motion",
"shimming",
"trim blocks",
"synchrotron radiation"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1107/s0909049597015756
PubMed: 15263531