Calibration and evaluation of uncertainty in the measurement of environmental electromagnetic fields.
← Research streamThe paper describes reference systems used to calibrate electromagnetic field meters at IEN and the Ivrea Department of ARPA, and discusses procedures to evaluate measurement uncertainty, including identifying and quantifying uncertainty components from meter…
Study snapshot
Abstract
After a brief description of the reference systems for the calibration of the electromagnetic field meters set up at IEN and the Ivrea Department of ARPA, the procedures for the evaluation of the measurement uncertainty are discussed, with reference to the problem of identifying and quantifying the different uncertainty components. which are due both to the field meter characteristics and to the measurement procedure and conditions. The problem of how to compare a measurement result, which consists of the measurement value and its associated uncertainty, with a limit fixed by the standards is also faced.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
The paper describes reference systems used to calibrate electromagnetic field meters at IEN and the Ivrea Department of ARPA, and discusses procedures to evaluate measurement uncertainty, including identifying and quantifying uncertainty components from meter characteristics and measurement procedures/conditions. It also addresses how to compare a measurement result (value plus associated uncertainty) with limits set by standards.
Outcomes measured
- Calibration reference systems for electromagnetic field meters
- Procedures for evaluating measurement uncertainty in environmental EMF measurements
- Identification/quantification of uncertainty components (instrument and procedure/conditions)
- Comparison of measured values (with uncertainty) to standards limits
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": null,
"source": "environmental",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Calibration reference systems for electromagnetic field meters",
"Procedures for evaluating measurement uncertainty in environmental EMF measurements",
"Identification/quantification of uncertainty components (instrument and procedure/conditions)",
"Comparison of measured values (with uncertainty) to standards limits"
],
"main_findings": "The paper describes reference systems used to calibrate electromagnetic field meters at IEN and the Ivrea Department of ARPA, and discusses procedures to evaluate measurement uncertainty, including identifying and quantifying uncertainty components from meter characteristics and measurement procedures/conditions. It also addresses how to compare a measurement result (value plus associated uncertainty) with limits set by standards.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"calibration",
"electromagnetic field meters",
"environmental electromagnetic fields",
"measurement uncertainty",
"standards limits",
"reference systems"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1093/oxfordjournals.rpd.a006690
PubMed: 11878421
Related papers
- Compact Exposimeter Device for the Characterization and Recording of Electromagnetic Fields from 78 MHz to 6 GHz with Several Narrow Bands (300 kHz) 2021
- A real-world quality assessment study in six ExpoM-RF measurement devices 2020
- Correcting errors in eye-position data arising from the distortion of magnetic fields by display devices. 2000
- 50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation. 2024
- Performance Evaluation and Calibration of Electromagnetic Field (EMF) Area Monitors Using a Multi-Wire Transverse Electromagnetic (MWTEM) Transmission Line. 2025
- Evaluation of aperture efficiency of a radiofrequency electric field strength meter antenna. 1997