A radiofrequency modified maze and valve procedure through a port-access approach.
← Research streamIn 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacema…
Study snapshot
Abstract
BACKGROUND: The aim of the study was to assess the feasibility and effectiveness of the irrigated radiofrequency modified maze procedure through a port-access approach during mitral valve surgery. METHODS: Forty-three patients with atrial fibrillation (AF) and mitral valve disease underwent a combined procedure through a port-access approach. The indication was a history of continuous AF for more than 6 months in patients eligible for minimally invasive mitral valve surgery. RESULTS: The incidence of early mortality was 1 patient (2.3%), and that of freedom from AF was 100% at the end of the operation (70% of patients with normal sinus rhythm, 30% with a pacemaker). One patient (2.3%) required permanent pacemaker implantation after surgery. One patient (2.3%) required reoperation for bleeding. There were no reoperations for failed valve repairs. The incidences of freedom from AF were 87% and 92% at 6 and 12 months, respectively. At 12 months, functional capacity had improved significantly (P < .05). There were no procedure-related complications. No thromboembolic events were detected during follow-up. CONCLUSION: The port-access approach provided a good access for both valve surgery and the radiofrequency maze procedure. The combination of direct and videoscopic vision allowed an adequate view and led to a safe and efficient combined procedure. Short- and intermediate-term follow-up results were favorable.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.
Outcomes measured
- Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery
- Early mortality
- Freedom from atrial fibrillation (end of operation; 6 and 12 months)
- Need for permanent pacemaker implantation
- Reoperation for bleeding
- Reoperation for failed valve repair
- Functional capacity at 12 months
- Procedure-related complications
- Thromboembolic events during follow-up
Limitations
- No control/comparator group described in the abstract
- Follow-up limited to short/intermediate term (reported to 12 months)
- Frequency/dose parameters of radiofrequency energy not reported in the abstract
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "medical radiofrequency ablation (surgical maze procedure)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Patients with atrial fibrillation and mitral valve disease undergoing minimally invasive mitral valve surgery",
"sample_size": 43,
"outcomes": [
"Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery",
"Early mortality",
"Freedom from atrial fibrillation (end of operation; 6 and 12 months)",
"Need for permanent pacemaker implantation",
"Reoperation for bleeding",
"Reoperation for failed valve repair",
"Functional capacity at 12 months",
"Procedure-related complications",
"Thromboembolic events during follow-up"
],
"main_findings": "In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.",
"effect_direction": "benefit",
"limitations": [
"No control/comparator group described in the abstract",
"Follow-up limited to short/intermediate term (reported to 12 months)",
"Frequency/dose parameters of radiofrequency energy not reported in the abstract"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"modified maze procedure",
"port-access",
"minimally invasive",
"mitral valve surgery",
"atrial fibrillation",
"pacemaker",
"follow-up"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: Not supplied
PubMed: 14721796
Related papers
- Radiofrequency Pulmonary Vein Isolation in a Patient with Dextrocardia With Situs Inversus Totalis. 2017
- [Radiofrequency ablation can reverse the abnormal circulating microRNA expression changes in patients with atrial fibrillation]. 2015
- Visualization of the radiofrequency lesion after pulmonary vein isolation using delayed enhancement magnetic resonance imaging fused with magnetic resonance angiography. 2015
- Visualizing radiofrequency lesions using delayed-enhancement magnetic resonance imaging in patients with atrial fibrillation: A modification of the method used by the University of Utah group. 2015
- Integrated procedure for giant right coronary aneurysm with fistula and atrial fibrillation--coronary grafting, fistula obliteration and radiofrequency maze. 2004
- Ensuring transmurality using irrigated radiofrequency modified maze in surgery for atrial fibrillation--a simple and effective way. 2004