A portable, low-power, wireless two-lead EKG system.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference · 2004 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 3610

The authors describe a custom-designed electrocardiograph sensor board (EKG on Mica2) and accompanying software (VitalEKG) to capture and wirelessly transmit heart activity traces. Preliminary test results are reported to validate the approach and suggest fea…

Study snapshot

PublicationConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference · 2004
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

Sensor devices ("motes") which integrate an embedded microprocessor, low-power radio and a limited amount of storage have the potential to significantly enhance the provision of emergency medical care. Wearable vital sign sensors can wirelessly monitor patient condition, alerting healthcare providers to changes in status while simultaneously delivering data to a backend archival system for longer-term storage. As part of the CodeBlue initiative at Harvard University, we previously developed a mote-based pulse oximetry module which gathers data from a noninvasive finger sensor and transmits it wirelessly to a base station. To expand the capabilities of the mote for healthcare applications we now introduce EKG on Mica2, the first custom-designed electrocardiograph sensor board to interface with this platform. We additionally present VitalEKG, a collection of software components which allow the capture and wireless transmission of heart activity traces. We present preliminary test results which validate our approach and suggest the feasibility of future enhancements.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposureNot supplied
Evidence strengthInsufficientConfidence: 74% · Peer reviewed: yes

Main findings

The authors describe a custom-designed electrocardiograph sensor board (EKG on Mica2) and accompanying software (VitalEKG) to capture and wirelessly transmit heart activity traces. Preliminary test results are reported to validate the approach and suggest feasibility of future enhancements.

Outcomes measured

  • Feasibility of a portable, low-power wireless two-lead EKG system
  • Wireless capture and transmission of EKG/heart activity traces
  • Preliminary test validation of the approach

Limitations

  • No EMF exposure parameters (e.g., frequency, power, SAR) are provided in the abstract.
  • No health effects assessment is described; the focus is on device design and feasibility.
  • Sample size and testing conditions are not reported in the abstract.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "low-power radio (wireless transmission)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Feasibility of a portable, low-power wireless two-lead EKG system",
    "Wireless capture and transmission of EKG/heart activity traces",
    "Preliminary test validation of the approach"
  ],
  "main_findings": "The authors describe a custom-designed electrocardiograph sensor board (EKG on Mica2) and accompanying software (VitalEKG) to capture and wirelessly transmit heart activity traces. Preliminary test results are reported to validate the approach and suggest feasibility of future enhancements.",
  "effect_direction": "unclear",
  "limitations": [
    "No EMF exposure parameters (e.g., frequency, power, SAR) are provided in the abstract.",
    "No health effects assessment is described; the focus is on device design and feasibility.",
    "Sample size and testing conditions are not reported in the abstract."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "wireless",
    "low-power radio",
    "motes",
    "wearable sensors",
    "EKG",
    "electrocardiograph",
    "CodeBlue",
    "Mica2",
    "VitalEKG",
    "emergency medical care"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1109/iembs.2004.1403627
PubMed: 17272147

Read the original paper →

Related papers

← Back to the Research Library