A dual band wireless power and data telemetry for retinal prosthesis.
← Research streamThe authors propose a dual-band inductive telemetry system using a lower frequency for power and a higher frequency for data. A prototype for a retinal prosthetic device was built; experimental results indicated that power and data could be transmitted and th…
Study snapshot
Abstract
Inductive coupling is commonly used for wireless power and data transfer in biomedical telemetry systems. The increasing demand on the performance of medical devices requires high data rate and high power efficiency at the same time. If only one radio frequency carrier is used, it is difficult to achieve both high data rate and high power efficiency due to the competing requirements on carrier frequency and system-Q of the power and data transmission. We propose a dual band telemetry system to implement power and data transmission using different frequencies by allocating lower frequency for power transmission and higher frequency for data transmission. However, the magnetic coupling between the power carrier and data carrier will affect the operation of both links. In this paper, this interference is analyzed and design equations are derived, which are used to design coils to maximize the data signal level received at the implant side. A prototype of dual band telemetry for a retinal prosthetic device has been built and experimental results show that both power and data can be transmitted and high data rate can be achieved without compromising the power transmission efficiency.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
The authors propose a dual-band inductive telemetry system using a lower frequency for power and a higher frequency for data. A prototype for a retinal prosthetic device was built; experimental results indicated that power and data could be transmitted and that high data rate could be achieved without compromising power transmission efficiency.
Outcomes measured
- Power transmission efficiency
- Data transmission/data rate
- Interference between power and data carriers
- Received data signal level at implant side
Limitations
- Frequencies and exposure metrics (e.g., field strength, SAR) are not reported in the abstract.
- No biological or health outcomes are described; the work focuses on engineering performance.
- Prototype/experimental details (setup, quantitative results) are not provided in the abstract.
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "RF",
"source": "implant telemetry (inductive coupling)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Power transmission efficiency",
"Data transmission/data rate",
"Interference between power and data carriers",
"Received data signal level at implant side"
],
"main_findings": "The authors propose a dual-band inductive telemetry system using a lower frequency for power and a higher frequency for data. A prototype for a retinal prosthetic device was built; experimental results indicated that power and data could be transmitted and that high data rate could be achieved without compromising power transmission efficiency.",
"effect_direction": "unclear",
"limitations": [
"Frequencies and exposure metrics (e.g., field strength, SAR) are not reported in the abstract.",
"No biological or health outcomes are described; the work focuses on engineering performance.",
"Prototype/experimental details (setup, quantitative results) are not provided in the abstract."
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"inductive coupling",
"wireless power transfer",
"data telemetry",
"dual band",
"retinal prosthesis",
"implant",
"interference",
"coil design"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1109/iembs.2006.260470
PubMed: 17946243
Related papers
- Wireless platform for multi-channel analog measurements. 2006
- External RF-EMF alters cell number and ROS balance possibly via the regulation of NADPH metabolism 2024
- IEC/IEEE Draft International Standard - Assessment methods of the human exposure to electric and 2024
- Bio-Electromagnetic Safety Assessment of Wireless Charging Environment for Electric Vehicles 2024
- Biological issue of electromagnetic fields and waves 2024
- Coverage factors for efficient demonstration of compliance of low-frequency magnetic near-field exposures with basic restrictions 2022