[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation · 2011 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 3222

A mobile phone–based wireless blood pressure monitoring system using Bluetooth transmission was developed. Experiments were conducted to demonstrate the device's reliability and stability, and the system was used to explore variations in blood pressure by tim…

Study snapshot

PublicationZhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation · 2011
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

A novel system which could measure blood pressure wirelessly through mobile phone has been proposed and developed. It consisted of a blood pressure signal recorder based on MCU (Micro Control Unit), which could transmit measured data via Bluetooth, and a software embedded on mobile phone, which could calculate the value of blood pressure and the rate of heart beat. The measurement results could easily be stored in text documents or in picture format. Detailed scheme and design of each module in the system was illustrated and experiments were conducted to demonstrate the reliability and stability of the device. A series of new conceptual explorations into blood pressure related issues were conducted with this system, including the variational blood pressure at different time periods in a day, the effect of posture on the measurement results and the impact of movements on blood pressure.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposureNot supplied
Evidence strengthInsufficientConfidence: 66% · Peer reviewed: yes

Main findings

A mobile phone–based wireless blood pressure monitoring system using Bluetooth transmission was developed. Experiments were conducted to demonstrate the device's reliability and stability, and the system was used to explore variations in blood pressure by time of day, posture, and movement.

Outcomes measured

  • blood pressure measurement (wireless)
  • heart beat rate calculation
  • device reliability and stability

Limitations

  • No sample size or participant characteristics reported in the abstract.
  • No quantitative performance metrics or statistical results provided in the abstract.
  • Exposure parameters (e.g., frequency, power, SAR) not described.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "mobile phone",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "blood pressure measurement (wireless)",
    "heart beat rate calculation",
    "device reliability and stability"
  ],
  "main_findings": "A mobile phone–based wireless blood pressure monitoring system using Bluetooth transmission was developed. Experiments were conducted to demonstrate the device's reliability and stability, and the system was used to explore variations in blood pressure by time of day, posture, and movement.",
  "effect_direction": "unclear",
  "limitations": [
    "No sample size or participant characteristics reported in the abstract.",
    "No quantitative performance metrics or statistical results provided in the abstract.",
    "Exposure parameters (e.g., frequency, power, SAR) not described."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.66,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mobile phone",
    "wireless",
    "Bluetooth",
    "blood pressure monitoring",
    "MCU",
    "heart rate",
    "device design",
    "reliability",
    "stability"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: Not supplied
PubMed: 22379764

Read the original paper →

Related papers

← Back to the Research Library