Comparison between different thickness umbrella-shaped expandable radiofrequency electrodes (SuperSlim and CoAccess): Experimental and clinical study.
← Research streamIn ex vivo bovine liver experiments, the CoAccess electrode produced significantly greater ablation area and longer ablation time than the SuperSlim electrode for several algorithms, with no significant difference for the additional low-power ablation algorit…
Study snapshot
Abstract
The purpose of the present study was to compare the size and configuration of the ablation zones created by SuperSlim and CoAccess electrodes, using various ablation algorithms in ex vivo bovine liver and in clinical cases. In the experimental study, we ablated explanted bovine liver using 2 types of electrodes and 4 ablation algorithms (combinations of incremental power supply, stepwise expansion and additional low-power ablation) and evaluated the ablation area and time. In the clinical study, we compared the ablation volume and the shape of the ablation zone between both electrodes in 23 hepatocellular carcinoma (HCC) cases with the best algorithm (incremental power supply, stepwise expansion and additional low-power ablation) as derived from the experimental study. In the experimental study, the ablation area and time by the CoAccess electrode were significantly greater compared to those by the SuperSlim electrode for the single-step (algorithm 1, p=0.0209 and 0.0325, respectively) and stepwise expansion algorithms (algorithm 2, p=0.0002 and <0.0001, respectively; algorithm 3, p= 0.006 and 0.0407, respectively). However, differences were not significant for the additional low-power ablation algorithm. In the clinical study, the ablation volume and time in the CoAccess group were significantly larger and longer, respectively, compared to those in the SuperSlim group (p=0.0242 and 0.009, respectively). Round ablation zones were acquired in 91.7% of the CoAccess group, while irregular ablation zones were obtained in 45.5% of the SuperSlim group (p=0.0428). In conclusion, the CoAccess electrode achieves larger and more uniform ablation zones compared with the SuperSlim electrode, though it requires longer ablation times in experimental and clinical studies.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In ex vivo bovine liver experiments, the CoAccess electrode produced significantly greater ablation area and longer ablation time than the SuperSlim electrode for several algorithms, with no significant difference for the additional low-power ablation algorithm. In 23 HCC clinical cases using the selected best algorithm, CoAccess had significantly larger ablation volume and longer ablation time, and more often produced round ablation zones compared with SuperSlim.
Outcomes measured
- Ablation zone size/area
- Ablation volume
- Ablation time
- Ablation zone shape/configuration (round vs irregular)
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "radiofrequency ablation electrodes (SuperSlim, CoAccess)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Clinical cases with hepatocellular carcinoma (HCC)",
"sample_size": 23,
"outcomes": [
"Ablation zone size/area",
"Ablation volume",
"Ablation time",
"Ablation zone shape/configuration (round vs irregular)"
],
"main_findings": "In ex vivo bovine liver experiments, the CoAccess electrode produced significantly greater ablation area and longer ablation time than the SuperSlim electrode for several algorithms, with no significant difference for the additional low-power ablation algorithm. In 23 HCC clinical cases using the selected best algorithm, CoAccess had significantly larger ablation volume and longer ablation time, and more often produced round ablation zones compared with SuperSlim.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency ablation",
"electrode design",
"SuperSlim",
"CoAccess",
"bovine liver",
"hepatocellular carcinoma",
"ablation zone",
"ablation volume",
"procedure time"
],
"suggested_hubs": [
{
"slug": "engineering",
"weight": 0.6,
"reason": "Compares performance of two radiofrequency ablation electrode designs in ex vivo and clinical settings."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.3892/etm.2011.347
PubMed: 22977647
Related papers
- The imprint of radiofrequency in the management of hepatocellular carcinoma. 2006
- Removal of liver tumours using radiofrequency waves. 2001
- Radiofrequency reduction of inferior turbinates in allergic and non allergic rhinitis. 2014
- [Radiofrequency aviation treatment for lingual root obstructive sleep apnea-hypopnea syndrome]. 2008
- [Radiofrequency ablation can reverse the abnormal circulating microRNA expression changes in patients with atrial fibrillation]. 2015
- Visualizing radiofrequency lesions using delayed-enhancement magnetic resonance imaging in patients with atrial fibrillation: A modification of the method used by the University of Utah group. 2015