Electric field in a plasma channel in a high-pressure nanosecond discharge in hydrogen: a coherent anti-stokes Raman scattering study.
← Research streamIn a hydrogen nanosecond discharge (2–3×10^5 Pa) ignited by a ~100 kV, ~5 ns pulse, an electric field was observed in the plasma channel with root-mean-square intensities up to 30 kV/cm. Polarization measurements indicated the field direction is along the cat…
Study snapshot
Abstract
Experimental results of a study of the electric field in a plasma channel produced during nanosecond discharge at a H2 gas pressure of (2-3)×10(5) Pa by the coherent anti-Stokes scattering method are reported. The discharge was ignited by applying a voltage pulse with an amplitude of ∼100 kV and a duration of ∼5 ns to a blade cathode placed at a distance of 10 and 20 mm from the anode. It was shown that this type of gas discharge is characterized by the presence of an electric field in the plasma channel with root-mean-square intensities of up to 30 kV/cm. Using polarization measurements, it was found that the direction of the electric field is along the cathode-anode axis.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In a hydrogen nanosecond discharge (2–3×10^5 Pa) ignited by a ~100 kV, ~5 ns pulse, an electric field was observed in the plasma channel with root-mean-square intensities up to 30 kV/cm. Polarization measurements indicated the field direction is along the cathode–anode axis.
Outcomes measured
- Electric field intensity in plasma channel (RMS, kV/cm)
- Electric field direction (cathode-anode axis)
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "high-pressure nanosecond gas discharge (plasma channel) in hydrogen",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "~5 ns voltage pulse"
},
"population": null,
"sample_size": null,
"outcomes": [
"Electric field intensity in plasma channel (RMS, kV/cm)",
"Electric field direction (cathode-anode axis)"
],
"main_findings": "In a hydrogen nanosecond discharge (2–3×10^5 Pa) ignited by a ~100 kV, ~5 ns pulse, an electric field was observed in the plasma channel with root-mean-square intensities up to 30 kV/cm. Polarization measurements indicated the field direction is along the cathode–anode axis.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"plasma channel",
"nanosecond discharge",
"hydrogen",
"electric field",
"coherent anti-Stokes Raman scattering",
"CARS",
"high pressure",
"polarization measurements"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1103/physrevlett.111.255001
PubMed: 24483746
Related papers
- High Frequency Electromagnetic Field Exposure in Paediatric and Female Patients with Implanted 2024
- Electrostatic pollination by butterflies and moths 2024
- Evaluating radiofrequency electromagnetic field exposure in confined spaces: a systematic review of recent studies and future directions 2024
- Electric and magnetic field pollution in near substations and investigation of anxiety and depressive 2024
- Measurement of non-ionizing radiation (NIR) from Wi-Fi access points and microwave ovens in 2025
- Evaluation of Population Exposure to Radiofrequency Fields in Microenvironments in the Cities of 2024