Magnetic field tunability of optical microfiber taper integrated with ferrofluid.

Optics express · 2013 · Unclear · Insufficient evidence

← Research stream
UnclearInsufficient evidencePaper 3109

The spectral characteristics of an S-tapered optical microfiber integrated with ferrofluid were theoretically analyzed and experimentally demonstrated to be highly dependent on magnetic-field intensity. Transmission loss and dip wavelength were adjustable wit…

Study snapshot

PublicationOptics express · 2013
Study typeengineering
Reported directionUnclear
Evidence ratingInsufficient

Abstract

Optical microfiber taper has unique propagation properties, which provides versatile waveguide structure to design the tunable photonic devices. In this paper, the S-tapered microfiber is fabricated by using simple fusion spicing. The spectral characteristics of microfiber taper integrated with ferrofluid under different magnetic-field intensities have been theoretically analyzed and experimentally demonstrated. The spectrum are both found to become highly magnetic-field-dependent. The results indicate the transmission and wavelength of the dips are adjustable by changing magnetic field intensity. The response of this device to the magnetic field intensity exhibits a Langvin function. Moreover, there is a linear relationship between the transmission loss and magnetic field intensity for a magnetic field intensity range of 25 to 200Oe, and the sensitivities as high as 0.13056dB/Oe and 0.056nm/Oe have been achieved, respectively. This suggests a potential application of this device as a tunable all-in-fiber photonic device, such as magneto-optic modulator, filter, and sensing element.

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionunclear
PopulationNot supplied
Sample sizeNot supplied
ExposureNot supplied
Evidence strengthInsufficientConfidence: 74% · Peer reviewed: yes

Main findings

The spectral characteristics of an S-tapered optical microfiber integrated with ferrofluid were theoretically analyzed and experimentally demonstrated to be highly dependent on magnetic-field intensity. Transmission loss and dip wavelength were adjustable with magnetic field intensity; a linear relationship between transmission loss and magnetic field intensity was reported over 25–200 Oe, with sensitivities up to 0.13056 dB/Oe and 0.056 nm/Oe.

Outcomes measured

  • Optical transmission loss vs magnetic field intensity
  • Wavelength shift (dip wavelength) vs magnetic field intensity
  • Magnetic-field-dependent spectral characteristics
  • Sensitivity (dB/Oe and nm/Oe)
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "magnetic field (device tuning)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Optical transmission loss vs magnetic field intensity",
    "Wavelength shift (dip wavelength) vs magnetic field intensity",
    "Magnetic-field-dependent spectral characteristics",
    "Sensitivity (dB/Oe and nm/Oe)"
  ],
  "main_findings": "The spectral characteristics of an S-tapered optical microfiber integrated with ferrofluid were theoretically analyzed and experimentally demonstrated to be highly dependent on magnetic-field intensity. Transmission loss and dip wavelength were adjustable with magnetic field intensity; a linear relationship between transmission loss and magnetic field intensity was reported over 25–200 Oe, with sensitivities up to 0.13056 dB/Oe and 0.056 nm/Oe.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "optical microfiber taper",
    "S-tapered microfiber",
    "ferrofluid",
    "magnetic field tunability",
    "magneto-optic",
    "photonic device",
    "sensor",
    "transmission loss",
    "wavelength shift",
    "Langvin function",
    "sensitivity"
  ],
  "suggested_hubs": []
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1364/oe.21.029914
PubMed: 24514542

Read the original paper →