Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines.
← Research streamElectric and magnetic field intensities were measured under coupled multi-line high voltage power systems and validated with finite element method simulations; results were compared with international standard limit values. The abstract does not report specif…
Study snapshot
Abstract
BACKGROUND: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. METHODS: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. RESULTS: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. CONCLUSION: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Electric and magnetic field intensities were measured under coupled multi-line high voltage power systems and validated with finite element method simulations; results were compared with international standard limit values. The abstract does not report specific exposure levels or whether limits were exceeded.
Outcomes measured
- Measured electric field intensity under high voltage lines at heights 0 m, 1 m, 1.5 m, 1.8 m
- Measured magnetic field intensity under high voltage lines at heights 0 m, 1 m, 1.5 m, 1.8 m
- Comparison of measured/simulated fields with international exposure limit values
Limitations
- No numerical results or whether exposure limits were exceeded are provided in the abstract
- Frequency of the fields is not stated
- No health outcomes or epidemiologic endpoints are reported; focus is on exposure characterization
- Sample size and measurement protocol details (e.g., number of locations/time points) are not provided
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "ELF",
"source": "high voltage power lines/substation",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Workers and people living in proximity of a high voltage substation (Annaba city, eastern Algeria)",
"sample_size": null,
"outcomes": [
"Measured electric field intensity under high voltage lines at heights 0 m, 1 m, 1.5 m, 1.8 m",
"Measured magnetic field intensity under high voltage lines at heights 0 m, 1 m, 1.5 m, 1.8 m",
"Comparison of measured/simulated fields with international exposure limit values"
],
"main_findings": "Electric and magnetic field intensities were measured under coupled multi-line high voltage power systems and validated with finite element method simulations; results were compared with international standard limit values. The abstract does not report specific exposure levels or whether limits were exceeded.",
"effect_direction": "unclear",
"limitations": [
"No numerical results or whether exposure limits were exceeded are provided in the abstract",
"Frequency of the fields is not stated",
"No health outcomes or epidemiologic endpoints are reported; focus is on exposure characterization",
"Sample size and measurement protocol details (e.g., number of locations/time points) are not provided"
],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"electric field",
"magnetic field",
"personal exposure",
"high voltage power lines",
"substation",
"finite element method",
"Algeria",
"international standards"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.78,
"reason": "Assesses EMF environment relevant to worker safety in high voltage substations"
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1016/j.shaw.2015.11.006
PubMed: 27340596
Related papers
- Electric and magnetic field pollution in near substations and investigation of anxiety and depressive 2024
- [A methodological approach to studying the values of 50-Hz electromagnetic fields that influence the workers of power enterprises]. 2009
- Extremely Low Frequency Electric and Magnetic Fields Exposure: Survey of Recent Findings 2023
- Assessment of the Electromagnetic Radiation Exposure at Electric Vehicle Charging Facilities 2022
- Investigation of extremely low-frequency (1 Hz-400 kHz) pollution frequently encountered in social life: a case study of a shopping mall 2022
- Near Field Exposure Conditions by UHF-RFID Systems in Smart Healthcare Environments 2021