Design, simulation and evaluation of uniform magnetic field systems for head-free eye movement recordings with scleral search coils.
← Research streamFinite element and numerical simulations of different coil geometries were performed and a 2.2 × 2.2 × 2.2 m coil frame (3 × 4 coils) was built to generate a 3D magnetic field. Measured flux density agreed with simulations, and the system produced a highly un…
Study snapshot
Abstract
The precise measurement of eye movements is important for investigating vision, oculomotor control and vestibular function. The magnetic scleral search coil technique is one of the most precise measurement techniques for recording eye movements with very high spatial (≈ 1 arcmin) and temporal (>kHz) resolution. The technique is based on measuring voltage induced in a search coil through a large magnetic field. This search coil is embedded in a contact lens worn by a human subject. The measured voltage is in direct relationship to the orientation of the eye in space. This requires a magnetic field with a high homogeneity in the center, since otherwise the field inhomogeneity would give the false impression of a rotation of the eye due to a translational movement of the head. To circumvent this problem, a bite bar typically restricts head movement to a minimum. However, the need often emerges to precisely record eye movements under natural viewing conditions. To this end, one needs a uniform magnetic field that is uniform over a large area. In this paper, we present the numerical and finite element simulations of the magnetic flux density of different coil geometries that could be used for search coil recordings. Based on the results, we built a 2.2 × 2.2 × 2.2 meter coil frame with a set of 3 × 4 coils to generate a 3D magnetic field and compared the measured flux density with our simulation results. In agreement with simulation results, the system yields a highly uniform field enabling high-resolution recordings of eye movements.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Finite element and numerical simulations of different coil geometries were performed and a 2.2 × 2.2 × 2.2 m coil frame (3 × 4 coils) was built to generate a 3D magnetic field. Measured flux density agreed with simulations, and the system produced a highly uniform field suitable for high-resolution eye movement recordings.
Outcomes measured
- Magnetic field (flux density) homogeneity/uniformity
- Agreement between simulated and measured magnetic flux density
- Feasibility for high-resolution eye movement recordings under head-free/natural viewing conditions
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": "magnetic scleral search coil recording system (coil frame generating 3D magnetic field)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Human subjects (contact lens with embedded search coil mentioned)",
"sample_size": null,
"outcomes": [
"Magnetic field (flux density) homogeneity/uniformity",
"Agreement between simulated and measured magnetic flux density",
"Feasibility for high-resolution eye movement recordings under head-free/natural viewing conditions"
],
"main_findings": "Finite element and numerical simulations of different coil geometries were performed and a 2.2 × 2.2 × 2.2 m coil frame (3 × 4 coils) was built to generate a 3D magnetic field. Measured flux density agreed with simulations, and the system produced a highly uniform field suitable for high-resolution eye movement recordings.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"scleral search coil",
"eye movement recording",
"uniform magnetic field",
"magnetic flux density",
"finite element simulation",
"coil geometry",
"3D magnetic field",
"field homogeneity"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1109/embc.2016.7590686
PubMed: 28268323
Related papers
- Human Exposure Influence Analysis for Wireless Electric Vehicle Battery Charging 2022
- The Effects of Uniform and Nonuniform Magnetic Fields in Plant Growth: A Meta-Analysis Approach 2023
- Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field. 2008
- Magnetodeformation effects and the swelling of ferrogels in a uniform magnetic field. 2010
- Chaos and reconnection in relativistic cyclotron motion in an elliptically polarized electric field. 1999
- Exploring Non-Thermal Mechanisms of Biological Reactions to Extremely Low-Frequency Magnetic 2024