Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.
← Research streamNumerical modeling showed that thin metallic wires implanted in biological tissues significantly increase local SAR at 900 and 1800 MHz. Despite high SAR gradients, temperature rises remain low (around 1°C) under exposure below current safety limits.
Study snapshot
Abstract
A numerical study to investigate the effects of the exposure to electromagnetic fields (EMF) at 900 and 1800 MHz on biological tissues implanted with thin metallic structures has been carried out, using the finite difference time domain (FDTD) solution technique. The results of the model show that the presence of a metallic wire yields to a significant increase in the local specific energy absorption rate (SAR). The present standards and/or guidelines on safe exposures of humans to EMF does not cover persons with implanted devices and thus the threshold levels to define safe exposure conditions might not apply in presence of high SAR gradients, such as the ones generated by thin metallic implanted objects. However, exposure to EMF fields below the actual safe levels even in presence of thin conductive structures cause rather low temperature rises (1 degrees C).
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Numerical modeling showed that thin metallic wires implanted in biological tissues significantly increase local SAR at 900 and 1800 MHz. Despite high SAR gradients, temperature rises remain low (around 1°C) under exposure below current safety limits.
Outcomes measured
- local specific energy absorption rate (SAR) increase
- temperature rise in tissues
Limitations
- Numerical study only, no in vivo or human data
- Focus on thin metallic wires only
- Temperature rise estimated, not measured directly
View raw extracted JSON
{
"study_type": "in_vitro",
"exposure": {
"band": "RF",
"source": null,
"frequency_mhz": 900,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"local specific energy absorption rate (SAR) increase",
"temperature rise in tissues"
],
"main_findings": "Numerical modeling showed that thin metallic wires implanted in biological tissues significantly increase local SAR at 900 and 1800 MHz. Despite high SAR gradients, temperature rises remain low (around 1°C) under exposure below current safety limits.",
"effect_direction": "mixed",
"limitations": [
"Numerical study only, no in vivo or human data",
"Focus on thin metallic wires only",
"Temperature rise estimated, not measured directly"
],
"evidence_strength": "low",
"confidence": 0.5,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"dosimetry",
"metallic implants",
"specific absorption rate",
"numerical modeling",
"finite difference time domain"
],
"suggested_hubs": []
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1109/iembs.2008.4650183
PubMed: 19163686
Related papers
- Assessment of the potential threats to brain health posed by the radiation from 5G sub-6 GHz base 2024
- Specific Absorption Rate Variability in Long Term Exposure In Vivo Experiments 2023
- Electromagnetic Exposure Dosimetry Study on Two Free Rats at 1.8 GHz via Numerical Simulation 2021
- Dosimetry of Various Human Bodies Exposed to Microwave Broadband Electromagnetic Pulses 2021
- Temperature distribution and Specific Absorption Rate inside a child's head 2017
- Specific absorption rate variation in a brain phantom due to exposure by a 3G mobile phone: problems in dosimetry. 2013