The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.
← Research streamThe abstract describes a technique to facilitate transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.
Study snapshot
Abstract
Transseptal puncture is a standard means of catheter access to the left atrium via the venous system, but carries a risk of cardiac perforation. Stretching and increased force to traverse the septum are required with elastic, aneurysmal, or thickened interatrial tissue. We describe a technique that facilitates transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
The abstract describes a technique to facilitate transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.
Outcomes measured
- Facilitation of transseptal puncture
- Risk of cardiac perforation (context)
Limitations
- No study design details provided in the abstract (e.g., controlled comparison, endpoints, follow-up).
- No sample size or participant characteristics reported.
- No quantitative safety or efficacy outcomes reported.
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "electrosurgical cautery generator (radiofrequency energy applied via transseptal needle tip)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "brief pulses"
},
"population": null,
"sample_size": null,
"outcomes": [
"Facilitation of transseptal puncture",
"Risk of cardiac perforation (context)"
],
"main_findings": "The abstract describes a technique to facilitate transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.",
"effect_direction": "unclear",
"limitations": [
"No study design details provided in the abstract (e.g., controlled comparison, endpoints, follow-up).",
"No sample size or participant characteristics reported.",
"No quantitative safety or efficacy outcomes reported."
],
"evidence_strength": "insufficient",
"confidence": 0.62,
"peer_reviewed_likely": "yes",
"keywords": [
"transseptal puncture",
"radiofrequency energy",
"electrosurgery",
"cautery generator",
"catheter access",
"left atrium"
],
"suggested_hubs": [
{
"slug": "engineering",
"weight": 0.55,
"reason": "Use of radiofrequency energy delivery system as a procedural technique in electrophysiology."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1111/j.1540-8167.2008.01323.x
PubMed: 19175842
Related papers
- Effect of cell phone-like electromagnetic radiation on primary human thyroid cells 2016
- Modeling tissue heating from exposure to RF energy & relevance of tissue heating to exposure limits 2018
- The role of electrolyte in lesion size using an irrigated radiofrequency electrode. 1997
- [ASSESSMENT OF OCCUPATIONAL EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS]. 2015
- Non-Ionizing Radiation in Swedish Health Care-Exposure and Safety Aspects. 2019