RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz
← Research streamNine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic res…
Study snapshot
Abstract
RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz Vermeeren G, Joseph W, Martens L. Radiofrequency exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz. Bioelectromagnetics. 2018 Apr;39(3):244-248. doi: 10.1002/bem.22113. No abstract Excerpts We investigated the exposure, in terms of both the peak spatial‐averaged specific absorption rate (SAR) in 10 g of tissue and the time-averaged root-mean-squared (RMS) electric (E) field, induced by baby monitors operating in a frequency range between 400 MHz and 2.45 GHz. We selected nine commercially available baby monitors ... Considering all investigated devices, the peak spatial SAR in 10 g ranged from 0.09 to 0.37 W/kg, which is 22.3- 5.4 times below the ICNIRP basic restriction. In summary, we measured the induced time-averaged root-mean-square electric field strength and the peak spatial-averaged specific absorption rate from the baby unit of nine commercially available devices and compared both with the ICNIRP guidelines. The communication technologies implemented in the baby monitors were: PMR446, continuous transmission at 864 MHz, DECT, and communication in the ISM band at 2450 MHz. The electric field was measured at a distance of 50 cm from the baby unit of the baby monitor. We measured the SAR in a flat phantom filled with head tissue simulating liquid and the baby unit touching the flat phantom. The maximum time-averaged root-mean-square electric field value closest to the ICNIRP reference level over all investigated devices was 1.51 V/m (for modern‐electronics DBS 3), which is 19.4 times below the ICNIRP reference level at 466 MHz. The peak spatial‐averaged SAR in 10 g of tissue was 0.37 W/kg in head simulating tissue (for Alecto-DBX-82), which is 5.4 times below the basic restriction of 2 W/kg as specified by ICNIRP. ncbi.nlm.nih.gov Note: The ICNIRP guidelines were designed to protect users only from short-term thermal effects.
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.
Outcomes measured
- Peak spatial-averaged SAR in 10 g tissue (W/kg)
- Time-averaged RMS electric field strength (V/m)
- Comparison with ICNIRP basic restrictions/reference levels
Limitations
- No abstract provided; information is from excerpts only
- E-field measurements were taken at a single stated distance (50 cm) from the baby unit
- SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom
- Only nine commercially available devices were selected; selection criteria not described in provided text
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "RF",
"source": "baby monitor",
"frequency_mhz": null,
"sar_wkg": 0.37,
"duration": null
},
"population": null,
"sample_size": 9,
"outcomes": [
"Peak spatial-averaged SAR in 10 g tissue (W/kg)",
"Time-averaged RMS electric field strength (V/m)",
"Comparison with ICNIRP basic restrictions/reference levels"
],
"main_findings": "Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.",
"effect_direction": "no_effect",
"limitations": [
"No abstract provided; information is from excerpts only",
"E-field measurements were taken at a single stated distance (50 cm) from the baby unit",
"SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom",
"Only nine commercially available devices were selected; selection criteria not described in provided text"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"baby monitor",
"baby surveillance devices",
"radiofrequency",
"RF exposure",
"SAR",
"10 g SAR",
"RMS electric field",
"PMR446",
"DECT",
"ISM 2450 MHz",
"ICNIRP"
],
"suggested_hubs": [
{
"slug": "who-icnirp",
"weight": 0.78,
"reason": "Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels."
}
]
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.1002/bem.22113
PubMed: Not supplied
Related papers
- Electromagnetic exposure analysis of the subway passenger under the civil communication system 2024
- Comparison of electromagnetic exposure for passengers at different positions on the subway platform 2022
- Impact of Small-Cell Deployment on Combined Uplink and Downlink RF Exposure Compared to the Status Quo in Mobile Networks 2021
- Electric Field and SAR Distribution in the Vicinity of Orthodontic Brace Exposed to the Cell Phone Radiation 2019
- Children exposure to femtocell in indoor environments estimated by sparse low-rank tensor approximations 2019
- Protective role of spermine against male reproductive aberrations induced by EMF exposure in the rat 2019