Evaluation of Temperature Elevation in Human Ocular Tissues due to Wireless Eyewear Devices

2019 · Harm · Low evidence

← Research stream
HarmLow evidencePaper 1813

This numerical study reports that modeled temperature in the eyeball increases with exposure time and reaches a thermal steady state at about 30 minutes. Reported temperature increments across ocular tissues are between about 1.1°C and 1.7°C, with early incre…

Study snapshot

Publicationmanual · 2019
Study typeengineering
Reported directionHarm
Evidence ratingLow

Abstract

Evaluation of Temperature Elevation in Human Ocular Tissues due to Wireless Eyewear Devices Lan J, Du G. Evaluation of temperature elevation in human ocular tissues due to wireless eyewear devices. ACES Journal. 34(1):17-24. 2019. Abstract In this paper, a numerical study is proposed to evaluate the temperature variation in the human ocular tissues during the electromagnetic radiation exposure from wireless eyewear device. The results show that the temperature in the whole eyeball increases gradually as the exposure time goes on and could reach the thermal steady state at about 30 minutes. During this process, the temperature increments in different ocular tissues are between 1.1°C and 1.7°C. The results also show the maximal ratio of temperature increments in the initial 5 and 10 minutes to that of the whole steady state could reach to 42.9% and 69.2%, respectively. Therefore, we believe that electromagnetic radiation from wireless eyewear device might pose a threat on the health of the human eyes. People should decrease the talk time as soon as possible to protect their eyes from the possible health hazards. Finally, attention is paid to evaluate the relationship between the maximal SAR and the temperature increments. The results show the temperature increments do not increase in direct proportion to the maximal SAR, which indicates that the maximal SAR and the temperature increments should be taken into account simultaneously while evaluating the biological effect of microwave on the ocular tissues. Conclusions Based on the results evaluated in this paper, we find that the temperature in the whole eyeball increases gradually and reaches the thermal steady state at about 30 minutes during the EM exposure of wireless eyewear device. The temperature increments in different ocular tissues are from 1°C to 1.7°C. We, therefore, believe EM exposure from wireless eyewear device may pose a threat on the health of the eyes, especially for the lens which suffer from the maximal temperature increments. Meanwhile, the results also show that the maximal ratio of temperature increments in the initial 5 and 10 minutes exposure time to that of the complete thermal steady state could reach to 42.9% and 69.2%, respectively. Hence, wireless eyewear device users should shorten the usage time as soon as possible to protect their eyes from the possible health hazards. Finally, we evaluate the relationship between the maximal SAR and the temperature increments in the ocular tissues. We find that the temperature increments do not increase in direct proportion to the maximal SAR. Therefore, we believe the maximal SAR and the temperature increments should be taken into account simultaneously while evaluating the biological effect of microwave on the ocular tissues. This paper could provide valuable data for the establishment of related safety standards and future researches in the biological effect of microwave and human eyes. However, limited by the experimental condition, the experiment is not included. Therefore, conclusions presented in this paper are just indicative but not definitive. Open access paper: aces- society.org/includes/downloadpaper.php?of=ACES_Journal_January_2019_Paper_3&nf=19-1-3

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeengineering
Effect directionharm
PopulationHuman ocular tissues (numerical model)
Sample sizeNot supplied
Exposuremicrowave · Up to ~30 minutes (thermal steady state reported at ~30 min; early time points at 5 and 10 min)
Evidence strengthLowConfidence: 74% · Peer reviewed: yes

Main findings

This numerical study reports that modeled temperature in the eyeball increases with exposure time and reaches a thermal steady state at about 30 minutes. Reported temperature increments across ocular tissues are between about 1.1°C and 1.7°C, with early increases reaching up to 42.9% (5 min) and 69.2% (10 min) of the steady-state increment. The authors state that temperature increments did not increase in direct proportion to maximal SAR and suggest both SAR and temperature rise should be considered when evaluating biological effects.

Outcomes measured

  • Temperature elevation in ocular tissues
  • Time to thermal steady state
  • Relationship between maximal SAR and temperature increments

Limitations

  • Numerical study only; no experiment included
  • Authors note conclusions are indicative but not definitive
  • Frequency and exposure parameters (e.g., SAR values) are not provided in the abstract
View raw extracted JSON
{
  "publication_year": 2019,
  "study_type": "engineering",
  "exposure": {
    "band": "microwave",
    "source": "wireless eyewear device",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "Up to ~30 minutes (thermal steady state reported at ~30 min; early time points at 5 and 10 min)"
  },
  "population": "Human ocular tissues (numerical model)",
  "sample_size": null,
  "outcomes": [
    "Temperature elevation in ocular tissues",
    "Time to thermal steady state",
    "Relationship between maximal SAR and temperature increments"
  ],
  "main_findings": "This numerical study reports that modeled temperature in the eyeball increases with exposure time and reaches a thermal steady state at about 30 minutes. Reported temperature increments across ocular tissues are between about 1.1°C and 1.7°C, with early increases reaching up to 42.9% (5 min) and 69.2% (10 min) of the steady-state increment. The authors state that temperature increments did not increase in direct proportion to maximal SAR and suggest both SAR and temperature rise should be considered when evaluating biological effects.",
  "effect_direction": "harm",
  "limitations": [
    "Numerical study only; no experiment included",
    "Authors note conclusions are indicative but not definitive",
    "Frequency and exposure parameters (e.g., SAR values) are not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "stance": "concern",
  "stance_confidence": 0.86,
  "summary": "This paper presents a numerical evaluation of temperature variation in human ocular tissues during electromagnetic exposure from a wireless eyewear device. The model suggests ocular temperatures rise over time and reach a thermal steady state at about 30 minutes, with tissue temperature increments reported around 1.1°C to 1.7°C. The authors interpret these modeled temperature rises as a potential threat to eye health and recommend reducing usage time, while noting the conclusions are indicative because no experimental validation was performed.",
  "key_points": [
    "The study is a numerical (modeling) assessment of ocular temperature changes during exposure from a wireless eyewear device.",
    "Modeled temperature in the eyeball increased gradually with exposure time and reached steady state at about 30 minutes.",
    "Reported temperature increments across ocular tissues were approximately 1.1°C to 1.7°C.",
    "Early temperature rise was reported as up to 42.9% (5 minutes) and 69.2% (10 minutes) of the steady-state increment.",
    "The authors suggest the lens experiences the maximal temperature increment in their evaluation.",
    "The paper reports temperature increments did not scale in direct proportion to maximal SAR.",
    "No experimental component was included, and the authors state the conclusions are indicative rather than definitive."
  ],
  "categories": [
    "Dosimetry & Modeling",
    "Thermal Effects",
    "RF/Microwave Exposure"
  ],
  "tags": [
    "Wireless Eyewear",
    "Ocular Tissues",
    "Eye Lens",
    "Microwave Radiation",
    "Numerical Modeling",
    "Temperature Rise",
    "Thermal Steady State",
    "Specific Absorption Rate",
    "Exposure Duration",
    "Safety Standards"
  ],
  "keywords": [
    "wireless eyewear device",
    "ocular tissues",
    "temperature elevation",
    "thermal steady state",
    "SAR",
    "microwave",
    "electromagnetic radiation",
    "lens"
  ],
  "suggested_hubs": [],
  "social": {
    "tweet": "Numerical modeling study (ACES Journal, 2019) reports ocular tissue temperature rises during exposure from a wireless eyewear device, reaching steady state at ~30 min with ~1.1–1.7°C increments; authors call findings indicative (no experiments).",
    "facebook": "A 2019 ACES Journal paper uses numerical modeling to estimate temperature elevation in human ocular tissues during exposure from a wireless eyewear device. The model suggests temperatures rise over time and reach steady state at ~30 minutes, with reported increments around 1.1–1.7°C; the authors note conclusions are indicative because no experimental validation was included.",
    "linkedin": "Lan & Du (ACES Journal, 2019) present a numerical evaluation of ocular tissue temperature elevation during EM exposure from a wireless eyewear device. The model suggests steady state at ~30 minutes and tissue temperature increments of ~1.1–1.7°C; authors emphasize results are indicative (no experimental study) and discuss that temperature rise did not scale directly with maximal SAR."
  }
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: Not supplied
PubMed: Not supplied

Read the original paper →

Related papers

← Back to the Research Library