Identification of Environmental and Experimental Factors Influencing Human Perception of DC and AC Electric Fields

Bioelectromagnetics · 2021 · Mixed · Low evidence

← Research stream
MixedLow evidencePaper 1158

In an exposure laboratory study estimating individual perception thresholds in 11 participants, relative humidity was identified as an environmental factor influencing perception of AC and DC electric fields in different ways. Perception thresholds were repor…

Study snapshot

PublicationBioelectromagnetics · 2021
Study typeother
Reported directionMixed
Evidence ratingLow

Abstract

Identification of Environmental and Experimental Factors Influencing Human Perception of DC and AC Electric Fields Kathrin Jankowiak, Sarah Driessen, Andrea Kaifie, Simon Kimpeler, Thomas Krampert, Thomas Kraus, Dominik Stunder, Michael Kursawe. Identification of Environmental and Experimental Factors Influencing Human Perception of DC and AC Electric Fields. Bioelectromagnetics. 2021 May 11. doi: 10.1002/bem.22347. Abstract As part of the energy transition in Germany, high-voltage direct current (HVDC) lines producing DC electric fields (EF) are in planning. Since the human perception of DC EF was rarely investigated in the past, we aimed to identify environmental and experimental factors influencing the human perception of direct current (DC) EF, alternating current (AC) EF, and the co-exposure of DC EF and AC EF (hybrid EF) under whole-body exposure. Additionally, first estimates of DC EF and AC EF perception thresholds as well as differences in human perception of DC EF and AC EF concerning the type of sensation experienced and the affected body part were evaluated. A highly sophisticated exposure lab was built to expose participants to various EF strengths and ask for their assessment concerning the presence of an EF. To estimate the individual perception thresholds of 11 participants, the signal detection theory as well as the single-interval-adjustment matrix procedure were applied. Relative humidity could be identified as an environmental factor influencing the perception of AC EF and DC EF in different ways. An appropriate ramp slope and an exposure duration for future studies could be elaborated. Additionally, perception thresholds were lower under hybrid EF exposure than under DC EF or AC EF exposure alone. Cutaneous sensations evoked under DC EF and AC EF exposure were individually different and attributed to various parts of the body. Several environmental and experimental factors influencing the human perception of EF could be identified and provide an essential basis for a large-scale study. pubmed.ncbi.nlm.nih.gov

Machine Enhanced Logic

AI evidence extraction

Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.

Study typeother
Effect directionmixed
PopulationHuman participants in an exposure laboratory
Sample size11
ExposureELF
Evidence strengthLowConfidence: 78% · Peer reviewed: yes

Main findings

In an exposure laboratory study estimating individual perception thresholds in 11 participants, relative humidity was identified as an environmental factor influencing perception of AC and DC electric fields in different ways. Perception thresholds were reported to be lower under combined (hybrid) DC+AC exposure than under DC-only or AC-only exposure, and reported cutaneous sensations varied between individuals and body parts.

Outcomes measured

  • Perception of DC electric fields
  • Perception of AC electric fields
  • Perception thresholds for DC and AC electric fields
  • Perception under combined DC+AC (hybrid) electric fields
  • Type of sensation and affected body part
  • Influence of relative humidity on perception

Limitations

  • Small sample size (11 participants)
  • Specific laboratory exposure conditions may limit generalizability to real-world environments
  • Electric field strengths, exact exposure durations, and detailed threshold values are not provided in the abstract
View raw extracted JSON
{
  "publication_year": 2021,
  "study_type": "other",
  "exposure": {
    "band": "ELF",
    "source": "high-voltage power lines (HVDC/HVAC)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Human participants in an exposure laboratory",
  "sample_size": 11,
  "outcomes": [
    "Perception of DC electric fields",
    "Perception of AC electric fields",
    "Perception thresholds for DC and AC electric fields",
    "Perception under combined DC+AC (hybrid) electric fields",
    "Type of sensation and affected body part",
    "Influence of relative humidity on perception"
  ],
  "main_findings": "In an exposure laboratory study estimating individual perception thresholds in 11 participants, relative humidity was identified as an environmental factor influencing perception of AC and DC electric fields in different ways. Perception thresholds were reported to be lower under combined (hybrid) DC+AC exposure than under DC-only or AC-only exposure, and reported cutaneous sensations varied between individuals and body parts.",
  "effect_direction": "mixed",
  "limitations": [
    "Small sample size (11 participants)",
    "Specific laboratory exposure conditions may limit generalizability to real-world environments",
    "Electric field strengths, exact exposure durations, and detailed threshold values are not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "stance": "neutral",
  "stance_confidence": 0.66,
  "summary": "This laboratory study investigated factors affecting human perception of whole-body DC, AC, and combined (hybrid) electric fields in the context of planned HVDC lines. Using signal detection theory and an adjustment procedure in 11 participants, the authors report that relative humidity influenced perception and that hybrid exposure produced lower perception thresholds than DC-only or AC-only exposure. Reported sensations differed across individuals and body parts, and the work is presented as groundwork for a larger study.",
  "key_points": [
    "The study focused on human perception of DC, AC, and combined DC+AC electric fields under whole-body exposure.",
    "Perception thresholds were estimated in 11 participants using signal detection theory and a single-interval adjustment procedure.",
    "Relative humidity was identified as an environmental factor influencing perception of AC and DC fields differently.",
    "Hybrid (DC+AC) exposure was associated with lower perception thresholds than DC-only or AC-only exposure.",
    "The type of cutaneous sensation and the affected body part varied between individuals.",
    "The authors describe identifying experimental parameters (e.g., ramp slope and exposure duration) to inform future studies."
  ],
  "categories": [
    "ELF Electric Fields",
    "Human Laboratory Studies",
    "Exposure Assessment & Perception"
  ],
  "tags": [
    "HVDC Lines",
    "DC Electric Fields",
    "AC Electric Fields",
    "Hybrid Exposure",
    "Human Perception Thresholds",
    "Signal Detection Theory",
    "Relative Humidity",
    "Cutaneous Sensations",
    "Exposure Laboratory"
  ],
  "keywords": [
    "high-voltage direct current",
    "HVDC",
    "direct current electric field",
    "alternating current electric field",
    "hybrid electric field",
    "perception threshold",
    "relative humidity",
    "signal detection theory",
    "cutaneous sensation"
  ],
  "suggested_hubs": [
    {
      "slug": "power-lines",
      "weight": 0.86,
      "reason": "Study motivated by planned HVDC lines and examines perception of DC/AC electric fields relevant to transmission infrastructure."
    },
    {
      "slug": "occupational-exposure",
      "weight": 0.22,
      "reason": "Whole-body exposure in a lab context may relate to settings where people are near strong electric fields, though the abstract does not specify workers."
    }
  ],
  "social": {
    "tweet": "Lab study (n=11) examined human perception of whole-body DC, AC, and combined (hybrid) electric fields relevant to planned HVDC lines. Relative humidity influenced perception, and hybrid DC+AC exposure showed lower perception thresholds than DC-only or AC-only.",
    "facebook": "Researchers built an exposure lab to study how people perceive DC, AC, and combined (hybrid) electric fields in the context of planned HVDC power lines. In 11 participants, relative humidity affected perception, and hybrid exposure was linked to lower perception thresholds than DC-only or AC-only exposure.",
    "linkedin": "Bioelectromagnetics (2021): A laboratory study estimated individual perception thresholds for whole-body DC, AC, and hybrid (DC+AC) electric fields (n=11) using signal detection theory. Relative humidity influenced perception, and hybrid exposure produced lower reported thresholds than DC-only or AC-only, informing design of larger-scale studies."
  }
}
AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.

Identifiers and source

DOI: 10.1002/bem.22347
PubMed: 33973657

Read the original paper →

Related papers