The Effect of Mobile Radiation on the Oxidative Stress Biomarkers in Pregnant Mice
← Research streamIn pregnant mice, exposure to 900 MHz mobile radiation (2 W; power density 0.045 μW/cm2) for 8 hours/day for 10 days was reported to increase blood MDA and 8-OHdG and decrease total antioxidant capacity compared with controls. Co-exposure with vitamin C (200 …
Study snapshot
Abstract
The Effect of Mobile Radiation on the Oxidative Stress Biomarkers in Pregnant Mice Nargess Moghadasi, Iraj Alimohammadi, Ali Safari Variani, Azadeh Ashtarinezhad. The Effect of Mobile Radiation on the Oxidative Stress Biomarkers in Pregnant Mice. J Family Reprod Health. 2021 Sep;15(3):172-178. doi: 10.18502/jfrh.v15i3.7134. Abstract Objective: Due to the growing use of communication instruments such as cell phones and wireless devices, there is growing public concern about possible harmful effects, especially in sensitive groups such as pregnant women. This study aimed to investigate the oxidative stress induced by exposure to 900 MHz mobile phone radiation and the effect of vitamin C intake on reducing possible changes in pregnant mice. Materials and methods: Twenty-one pregnant mice were divided into three groups (control, mobile radiation- exposed, and mobile radiation plus with vitamin C intake co-exposed (200 mg /kg)). The mice in exposure groups were exposed to 900 MHz, 2 watts, and a power density of 0.045 μw /cm2 mobile radiation for eight hours/day for ten consecutive days. After five days of rest, MDA (Malondialdehyde), 8-OHdG (8-hydroxy-2' - deoxyguanosine), and TAC (Total Antioxidant Capacity) levels were measured in the blood of animals. The results were analyzed by SPSS.22.0 software. Results: The results showed that exposure to mobile radiation increased MDA (P=0.002), and 8-OHdG (P=0.001) significantly and decreased Total Antioxidant Capacity in the exposed groups (P=0.001). Taking vitamin C inhibited the significant increase in MDA and 8-OHdG levels in exposed groups. Conclusion: Although exposure to mobile radiation can cause oxidative stress in the blood of pregnant mice, vitamin C as an antioxidant can prevent it. Open access paper: ncbi.nlm.nih.gov
AI evidence extraction
Structured fields below were generated from the paper’s abstract and metadata to make the evidence easier to inspect. Automated extraction may be incomplete or incorrect; verify important details against the original paper.
Main findings
In pregnant mice, exposure to 900 MHz mobile radiation (2 W; power density 0.045 μW/cm2) for 8 hours/day for 10 days was reported to increase blood MDA and 8-OHdG and decrease total antioxidant capacity compared with controls. Co-exposure with vitamin C (200 mg/kg) was reported to inhibit the significant increases in MDA and 8-OHdG in exposed groups.
Outcomes measured
- Malondialdehyde (MDA)
- 8-hydroxy-2'-deoxyguanosine (8-OHdG)
- Total Antioxidant Capacity (TAC)
Limitations
- Animal study; findings may not generalize to humans.
- Small sample size (21 total across three groups).
- No SAR reported in the abstract.
- Exposure characterization is limited to frequency, power, and power density; dosimetry details are not provided in the abstract.
- Outcomes limited to blood oxidative stress biomarkers; no clinical or reproductive outcomes reported in the abstract.
View raw extracted JSON
{
"publication_year": 2021,
"study_type": "animal",
"exposure": {
"band": "RF",
"source": "mobile phone",
"frequency_mhz": 900,
"sar_wkg": null,
"duration": "8 hours/day for 10 consecutive days (then 5 days rest before blood sampling)"
},
"population": "Pregnant mice",
"sample_size": 21,
"outcomes": [
"Malondialdehyde (MDA)",
"8-hydroxy-2'-deoxyguanosine (8-OHdG)",
"Total Antioxidant Capacity (TAC)"
],
"main_findings": "In pregnant mice, exposure to 900 MHz mobile radiation (2 W; power density 0.045 μW/cm2) for 8 hours/day for 10 days was reported to increase blood MDA and 8-OHdG and decrease total antioxidant capacity compared with controls. Co-exposure with vitamin C (200 mg/kg) was reported to inhibit the significant increases in MDA and 8-OHdG in exposed groups.",
"effect_direction": "harm",
"limitations": [
"Animal study; findings may not generalize to humans.",
"Small sample size (21 total across three groups).",
"No SAR reported in the abstract.",
"Exposure characterization is limited to frequency, power, and power density; dosimetry details are not provided in the abstract.",
"Outcomes limited to blood oxidative stress biomarkers; no clinical or reproductive outcomes reported in the abstract."
],
"evidence_strength": "low",
"confidence": 0.78,
"peer_reviewed_likely": "yes",
"stance": "concern",
"stance_confidence": 0.74,
"summary": "This animal study examined whether 900 MHz mobile radiation induces oxidative stress in pregnant mice and whether vitamin C modifies these effects. The authors report increased blood MDA and 8-OHdG and decreased total antioxidant capacity after RF exposure versus controls. Vitamin C co-exposure was reported to inhibit the significant increases in MDA and 8-OHdG.",
"key_points": [
"Twenty-one pregnant mice were assigned to control, RF-exposed, or RF-exposed plus vitamin C groups.",
"Exposure was 900 MHz mobile radiation at 2 W and 0.045 μW/cm2 for 8 hours/day over 10 days.",
"Blood oxidative stress markers (MDA, 8-OHdG) increased and total antioxidant capacity decreased in exposed groups.",
"Vitamin C (200 mg/kg) was reported to inhibit the significant increases in MDA and 8-OHdG.",
"The abstract does not report SAR or detailed dosimetry beyond power and power density.",
"The outcomes are biomarker-based and do not include pregnancy or offspring endpoints in the abstract."
],
"categories": [
"Animal Studies",
"RF Exposure",
"Oxidative Stress",
"Pregnancy & Reproduction"
],
"tags": [
"Pregnant Mice",
"900 MHz",
"Mobile Phone Radiation",
"Radiofrequency Exposure",
"Oxidative Stress",
"Malondialdehyde",
"8-OHdG",
"Total Antioxidant Capacity",
"Vitamin C Supplementation",
"Antioxidants",
"Blood Biomarkers"
],
"keywords": [
"mobile radiation",
"900 MHz",
"pregnant mice",
"oxidative stress",
"MDA",
"8-OHdG",
"total antioxidant capacity",
"vitamin C"
],
"suggested_hubs": [
{
"slug": "cell-phones",
"weight": 0.9,
"reason": "Study investigates 900 MHz mobile phone radiation exposure."
}
],
"social": {
"tweet": "Animal study: pregnant mice exposed to 900 MHz mobile radiation (8 h/day for 10 days) showed higher blood MDA and 8-OHdG and lower total antioxidant capacity; vitamin C co-exposure was reported to inhibit increases in MDA and 8-OHdG.",
"facebook": "In a study of pregnant mice, 900 MHz mobile radiation exposure (8 hours/day for 10 days) was associated with increased oxidative stress biomarkers (MDA, 8-OHdG) and reduced total antioxidant capacity in blood. Vitamin C co-exposure was reported to inhibit the significant increases in MDA and 8-OHdG.",
"linkedin": "This animal study reports that 900 MHz mobile radiation exposure in pregnant mice increased blood oxidative stress biomarkers (MDA, 8-OHdG) and decreased total antioxidant capacity, while vitamin C co-exposure was reported to inhibit increases in MDA and 8-OHdG. Findings are biomarker-based and dosimetry details (e.g., SAR) are not provided in the abstract."
}
}AI-extracted fields are generated from the abstract and metadata and may be incomplete or incorrect. This material is for informational purposes and is not medical advice.
Identifiers and source
DOI: 10.18502/jfrh.v15i3.7134
PubMed: Not supplied
Related papers
- Evaluation of oxidative stress and genotoxicity of 900 MHz electromagnetic radiations using Trigonella foenum-graecum (fenugreek) test system 2022
- Impacts of exposure to 900 MHz mobile phone radiation on liver function in rats. 2015
- Lasting hepatotoxic effects of prenatal mobile phone exposure. 2017
- Effect of low level microwave radiation exposure on cognitive function and oxidative stress in rats. 2013
- Oxidative Stress Response of Honey Bee Colonies (Apis mellifera L.) during Long-Term Exposure at a Frequency of 900 MHz under Field Conditions 2024
- Investigation of oxidative damage, antioxidant balance, DNA repair genes, and apoptosis due to radiofrequency-induced adaptive response in mice 2022